Dimensions

Screen 1

Screen 2

Height: 1.125” (3.8cm)

Width: 3.75” (9.5cm) 
Length: 2.5” (6.2cm)

Software, Screens and Operation

 Upon powering up the unit, the software revision will be displayed

for about 5 seconds. If the “MODE” button is depressed the screen will stop

showing the revision and jump to the next screen.

SCREEN #1: r1-6 (Revision 1.6)

Next, the unit will advance to the default screen to indicate “Pxyz” where “P” 

equals the percentage of UV light detected as referenced to the baseline* and “xyz” 

represents the value of “P.” See instructions for SCREEN #5 to learn how to set 

the baseline. 

For example:

SCREEN #2: “P73” (the measured intensity is at 73%

of the maximum set intensity of 100%).

If the optional data logging is installed, after the revision the unit will scroll 
“data logger.”

Electrical Connections

Dry Contact Output

To remove a wire from the terminal block, insert a small athead screwdriver above

the terminal and gently pull out the wire.

Under normal operating conditions, the relay is energized.This means that a power

failure will trigger an alarm when the dry contacts are used. This is purposely done

so a power failure in the UV room can be monitored and signaled.

Slot for wire(s) removal

WARNING

Incorrect wiring will damage 
the unit and void the warranty.  
Make sure to double check all 
connections before powering 
on the unit. 