19
is damaged
B.Internal damage of the motor
Change the Motor.
C.Motor idling
When the current is too small, please
report the error. Please install the test.
E08-Storage
24C02
error
(outside 24C02
driver)
A.The storage IC is not plugged in (non-
switching power supply)
Re-insert into the IC holder, pay
attention to the PIN1 foot position.
B.The storage IC is damaged, or the
related line is bad.
Change the storage IC,or change the
Drive.
E09-Inverted error (with
inverted drive)
A.The treadmill is erected or placed
horizontally
Adjust the treadmill,placed
horizontally.
B.Bad drive inverted line
Change the Drive.
E10-Usually the motor
instantaneous
peak
current
abnormality,
over current protection
A.Drive torque is too large
Adjust the torque potentiometer to the
proper position.
B.Internal short circuit of the motor
Change the Motor.
C.The drive part is stuck
Adjust the transmission part, or add
lubricant
E11-External
AC
voltage
over
voltage
(according to customer
requirements)
AC over voltage: higher than 270VAC
for 220V system; higher than 150VAC
for 110V system
Stop using, ask the electrician to
troubleshoot
E14-External
AC
voltage under voltage
(according to customer
requirements)
AC under voltage: less than 160VAC
for 220V systems; less than 70VAC for
110V systems
Stop using, ask the electrician to
troubleshoot