16. 

EC DECLARATION OF CONFORMITY 

 

Manufacturer: 

Fremco A/S 

Ellehammervej 14 
DK-9900 Frederikshavn 
Denmark 

We hereby declare that 

101-1909110001 Nanoflow MAX fiber blowing machine 

from Serial No. 9328.3023 

 

is manufactured in conformity with the EC Directives  

EC Directives: 

 

2006/42/EC

 

 the Machinery Directive 

The directive has the dual aim of harmonising the health and safety requirements applicable to machinery on 

the basis of a high level of protection of health and safety, while ensuring the free circulation of machinery on 
the EU market.  

2014/30/EU

 - Electromagnetic Compatibility (EMC) Directive

 

The directive ensures that electrical and electronic equipment does not generate, or is not affected by, 
electromagnetic disturbance. 

2014/35/EU

 

 The Low Voltage Directive

 

The directive ensures that electrical equipment within certain voltage limits provides a high level of protection 
for European citizens, and benefits fully from the Single Market 
 

International standards:  

 

 

 

DS/EN ISO 12100:2011

- Safety of machinery 

The standard specifies basic terminology, principles and a methodology for achieving safety in the design of 
machinery. It specifies principles of risk assessment and risk reduction to help designers in achieving this 

objective 
 

European standards: 

 

 

 

DS/EN ISO 4414:2010

 - Pneumatic fluid power 

ISO 4414:2010 deals with all significant hazards associated with pneumatic fluid power systems and specifies 

principles to apply in order to avoid those hazards when the systems are put to their intended use. 
 

Technical file responsible: 

Kasper Mikkelsen 
Research & Development Manager 
Ellehammervej 14, DK-9900 Frederikshavn 

 

Attested by:

 

 

 

 

 

Kim Lindblad Carlsen 

 

 

Kasper Mikkelsen 

Managing Director 

 

 

R&D Manager 

Frederikshavn, 15.10.2019   

 

Frederikshavn, 01.07.2021 

Summary of Contents for 101-190911001

Page 1: ...N DENMARK VAT NO DK30815416 TELEPHONE 45 7230 1213 SALES FREMCO DK WWW FREMCO DK THIS MATERIAL IS COPYRIGHT PROTECTED NanoFlow MAX For fiber dimension 0 8 4 5 mm Operating manual Responsible manufactu...

Page 2: ...ONS 6 4 SAFETY INSTRUCTIONS 7 5 MAINTENANCE 7 6 IDENTIFICATION 8 7 APPLICATION 8 8 MOUNTING 8 9 SUPPLY OF COMPRESSED AIR 8 10 FIBER PROTECTION 9 11 MACHINE OVERVIEW 10 12 RUNNING THE FIBER BLOWING MAC...

Page 3: ...tically included when you purchase your Fremco fiber blowing machine you automatically get our 12 months warranty You can then claim your additional 24 months warranty at any point during the followin...

Page 4: ...pplicable from machine serial number 9328 3023 Accessibility The instructions are to be kept in a location known to the staff and must be easily accessible for the operators and maintenance personnel...

Page 5: ...name Fremco A S Company address Ellehammervej 14 DK 9900 Frederikshavn 2 2 THE MACHINE S DESIGNATION The machine s complete designation is NanoFlow MAX 2 3 MACHINE PLATE The machine plate is situated...

Page 6: ...Denmark Item No 101 190911001 Fiber diameter 0 8 4 5 mm Duct diameter 3 12 7 mm Blowing distance Up to 1200 m 3940 ft Blowing speed Up to 125 m min 410 ft min Pushing force 0 2 kg Maximum air pressure...

Page 7: ...ecause you risk getting your fingers injured and make sure the fiber does not make loops that might be dangerous to persons around the machine Never wear loose clothing WARNING Loose clothing may beco...

Page 8: ...mes in a carrying case When the machine is not in use or during transportation always store it in the carrying case Charge the battery before operation 8 MOUNTING Make sure to place the machine on a s...

Page 9: ...iction in the duct The higher setting of torque the later this will happen At a point the blowing will stop as it is no longer possible to push the fiber with the chosen torque setting The display on...

Page 10: ...815416 TELEPHONE 45 7230 1213 SALES FREMCO DK WWW FREMCO DK 11 MACHINE OVERVIEW Adaptor Plates Inlet Guides Main Power Switch Step Switch Machine runs only when the Step switch is actuated Torque knob...

Page 11: ...5416 TELEPHONE 45 7230 1213 SALES FREMCO DK WWW FREMCO DK NB Too high clamping force can cause fiber damage After every fiber blowing deployment job the clamping force has to be reset to 1 This secure...

Page 12: ...uct quality of compressed air blowing length weather conditions etc Lift the support wheel and push the fiber in between the wheels approx 15 cm Release the support wheel to let it fall into place thu...

Page 13: ...move towards a stop and activate the fiber safety Valve for reverse airflow For removal of fiber from a duct use the valve to blow compressed air through the duct so that the fiber can be pulled out A...

Page 14: ...nd duct adaptors fit the actual size of the fiber and the duct Below is an overview of the different adaptor components for NanoFlow MAX Many different sizes of adaptor plates and duct adaptors for ma...

Page 15: ...E CHANGING ADAPTOR PLATES Preparation of adaptor kit for correct fiber and duct size Choose the correct size of adaptor plate to suit the fiber Choose the correct size of duct adaptor to suit the duct...

Page 16: ...the wheels are mounted correctly Make sure that machine and wheels are clean and free from grease and dirt The adaptor plates are not identical One is for the top and one is for the bottom The design...

Page 17: ...DK Like the adaptor plates the inlet guides are not identical One is for the top and one is for the bottom Like the adaptor plates the inlet guides must be at least 0 2 mm larger than the fiber Examp...

Page 18: ...Item No 103 160601064 1 Attach the water separator on the compressor s discharge nozzle 2 Attach air hose on the separator s discharge nozzle 3 Attach the opposite end of the air hose on the machine...

Page 19: ...lectromagnetic disturbance 2014 35 EU The LowVoltage Directive The directive ensures that electrical equipment within certain voltage limits provides a high level of protection for European citizens a...

Page 20: ...s are placed on the GB market by requiring manufacturers to show how their products meet the essential requirements 2016 No 1101 Electrical Equipment Safety regulations 2016 International standards DS...

Reviews: