1.
Clean the oil level sight glass. See
Fig. 6
.
2.
Check the fluid level in the sight glass. When the
fluid level is at or above 3/4 of the sight glass,
then it is at or above the minimum fill level. See
Fig. 7
.
3.
If the fluid level is low, check the transmission for
leaks, and correct as needed.
4.
If needed, add the recommended fluid, until it is
at or above 3/4 of the sight glass. See
Table 3
for approved transmission lubricants.
For more information and a complete listing of
approved lubricants, refer to the Eaton website,
www.roadranger.com
.
26–06 Eaton Fuller Manual
Transmission Air Filter/
Regulator Check,
Cleaning, or
Replacement
1.
Apply the parking brakes, and chock the rear
tires. Drain the air reservoirs.
WARNING
Drain the air supply; if the air supply is not
drained before the air filter/regulator is serviced,
serious injury and component damage could re-
sult.
2.
Clean the outside of the air filter/regulator with
cleaning solvent. See
Fig. 8
.
02/23/2015
f261460
1
2
3
1.
Drain Plug
2.
Fill Plug
3.
Sight Glass
Fig. 6, Eaton Fuller Transmission With a Sight Glass
02/23/2015
f261461
A
B
A. Full
B. Low
Fig. 7, Transmission Fluid Level Sight Glass
f260037a
05/27/93
Fig. 8, Air Filter/Regulator Location
Transmission
26
Cascadia Maintenance Manual, March 2016
26/6