Figure 3
PLACING AND SECURING THE OVEN
Place the oven into the cabin with two or more people.
Ensure that oven’s frame and front edge of the
furniture match uniformly.
Supply cord mustn’t be under the oven, squeeze
in between oven and furniture or bend.
Fix the oven to the furniture by using the
screws provided with the product. Screws must
be mounted as shown in
fi gure 5
by passing
them through plastics attached to frame of
the product. Screws mustn’t be overtightened.
Otherwise, screw sockets might be worn.
Check that oven doesn’t move after mounting.
If oven isn’t mounted in accordance with
instructions, there is a risk of tilt over during
operation.
Figure 5
ELECTRICAL CONNECTION
Mounting place of the product must have appropriate electrical installation.
Network voltage must be compatible with the values provided on type label of
product.
Product connection must be made in accordance with local and national electrical
requirements.
Before starting the mounting disconnect network power. Do not connect the
product to network until its mounting is completed.
The clearances with the dimensions indicated in the fi gure must be provided at the
rear part of cabin, upper and lower sections so that necessary ventilation can be
achieved.
INSTALLATION REQUIREMENTS
Product dimensions are provided in the
fi gure 3
.
INSTALLATION UNDER COUNTER
Cabin must match the dimensions provided in
fi gure 2
.
10
INSTALLATION OF APPLIANCE
INSTALLATION OF APPLIANCE
Figure 2
A clearance must be provided at the rear part of the cabin as indicated in the fi gure
so that necessary ventilation can be achieved.
After mounting, the clearance between lower and upper part of the counter is
indicated in
fi gure 5
with «A». It’s for ventilation and shouldn’t be covered.
INSTALLATION IN AN ELEVATED CABINET
Cabin must match the dimensions provided in
fi gure 4
.
Figure 4
Furniture surfaces for mounting
and mounting materials to be used
must have a minimum temperature
resistance of 100 °C.
Mounting cabin must be secured
and its fl oor must be plane for
product not to tilt over.
Cabin fl oor must have a minimum
strength that would handle a load of
60 kg.