12
TECHNICAL ASSISTANCE SERVICE
CLEANING
TECHNICAL ASSISTANCE SERVICE
Before contacting the Assistance Service:
•
Check whether it is possible to rectify the problem by referring to
the“Troubleshooting” guide.
•
Restart the appliance to check whether the problem has been resolved. If
theproblem still exists, disconnect the appliance from the mains electricity
supplyand repeat the operation after one hour.
If the appliance is not working properly or not working at all, before calling
theTechnical Assistance Service check that:
•
The plug is inserted properly in the mains socket.
•
The mains supply is working.
•
The temperature is set correctly.
•
The doors close properly.
•
The power supply voltage corresponds to that of the appliance (± 6%).
•
If the problem still exists, call the Assistance Service.
• INFORM THE ASSISTANCE SERVICE OF:
•
The type of malfunction
•
The appliance model
•
The serial number
The manufacturing firm refuses all responsibility for any possible imprecision in this
booklet, due to misprints or clerical errors. It reserves the right to make all the changes
that it will consider necessary in its own products, without effecting the essential
characteristics of functionality and safety.
CLEANING THE INTERNAL PLASTIC PARTS AND THE DOOR GASKET
Use a warm solution of bicarbonate of soda (two spoonfuls in two litres of water).
IMPORTANT!
Do not use abrasives or detergents of any kind.
CLEANING THE CONDENSER
This should be carried out at least twice a year.
Clean using a domestic vacuum cleaner or a brush (fig. 13). A dirty condenser will
have a negative effect on the appliance and reduce its performance.
FOR PROLONGED ABSENCES
•
Empty the compartments.
•
Disconnect the appliance from the mains electricity supply.
•
Clean both the compartments and dry them.
•
Leave the doors open to prevent bad smells or mould from forming.
ANTIBACTERIAL FILTER
The appliance is equipped with an antibacterial
filter; its function is to improve the air quality inside
the refrigerator, ensuring a healthier and bacteria-
free environment and, as a result, extending food
preservation.
CLEANING THE ANTIBACTERIAL FILTER
Perform cleaning the antibacterial filter every 4
months.
1. Remove the filter-holder cover (fig. 1.)
2. Remove the filter (fig. 2.)
3. Wash it with hot water (it can be washed also
in the dishwasher); dry it at a temperature
lower than 100°C;
4. Remount it in the specific seat and place back
the cover (fig. 1)
To maintain a proper filtering capacity, replace the
filter every 2 years.
TROUBLESHOOTING
1. The appliance does not work. Check that:
•
Is there a power cut?
•
Is the plug inserted properly in the mains socket?
•
Is the power supply cable damaged?
•
Is the temperature setting correct?
2. The temperature inside the compartments is not low enough. Check that:
•
Do the doors close properly?
•
Is the appliance installed near to a heat source?
•
Is the temperature setting correct?
•
Is the condenser clean?
3. The temperature inside the fridge compartment is too low. Check that:
•
Is the thermostat in the right position?
4. The appliance is very noisy. Check that:
•
Is the appliance in contact with other furniture or objects?
•
Are the pipes on the back touching or vibrating?
•
Is the appliance level?
5. The interior light does not work
•
Contact the Technical Assistance Service.
6. There is water on the floor. Check that:
•
Is tray V inserted correctly and in contact with the compressor?
•
Is drain pipe R correctly inserted in the tray?