Setup:
To program the modem, proceed as described in the Main Manual, with the following
exceptions:
•
Capital U on the diagnostics port brings up the setup menu.
•
You must use the diagnostic port (there's no RS232 Data Port in this modem)
•
You must select the following settings.
Setup Menus
NOTE: The Baud Rate setting is neither the over the air data rate of the Radio Link, nor the data
rate of the Ethernet 10Base-T connection to the LAN. This Baud Rate strictly sets the protocol
internal to the Modem, between the Ethernet Interface and the RF modem.
Menu 1,
SET BAUD RATE
Modem Baud is 1382400
Must be “9”
(1382.4Kbps)
(0) 230,400
(1) 115,200
…
(9) 1382.4KB
(A) Data, Parity
0
Must be "0"
(Default)
(B) MODBus RTU
0
Must be "0"
(Disabled)
(C) RS232/485
0
Must be "0"
(TTL)
(D) Setup Port
2
Must be "2"*
(Diagnostics port used for Set-up)
(E) TurnOffDelay 0 TurnOnDelay 0
No effect "0"
(Default for both)
(F) FlowControl
1
Must be "1"
(CTS flow control)
Menu 1, Submenu F
Ethernet/IP Radio Setup
(0) Ethernet Mode
1
Must be set to "1"*
(1) Half/Full Duplex
0
Select either, depending on your network
(2) Slave IP Stack
0
Must be set to “1”
(3) Slave UDP Mode
0
(4) IP Address
255.255.255.255
Used for diagnostics only
(5) Port Address
4131
Default Port Address
(6) IP Address 2
255.255.255.255
(7) Port Address 2
6535
(8) MAC Filter 0
0 disables internal MAC filter. 1 enables.
*NOTE
: Once the "Ethernet Mode" setting is set to 1 (Menu 0, Submenu F, Option 0), the "Set-Up
Port" (Menu1, option D) can no longer be changed. Therefore, it is important to ensure the "Set-
Up Port" is set at "2", prior to enabling the "Ethernet Mode".
LAD0013AB Rev H