background image

FreeWave Technologies 

 

HT Ethernet Addendum 

  

900MHz 

  

V1.0h 

Installation: 

 
To install the modem, proceed as described in the standard FGR user manual, with the following 
exceptions: 

 

Connect the modem to the LAN with a CAT5 RJ45 Ethernet cable. 

  Use the "Normal/Crossover" switch to select the polarity of the Ethernet connection. If 

connecting to a switch, router or hub, select "Normal".  If connecting to a NIC or a modem, 
select "Crossover".  However, if you are using a crossover cable, then use the opposite 
settings of the switch. 

 

If required, use the top row of LED’s for troubleshooting the Ethernet Interface. 

 

Troubleshooting: 

 

To troubleshoot the modem, proceed as described in the Main Manual.  Additionally, use the top 
row of LED’s in this Ethernet modem as troubleshooting tools. 
 

 

No data is being passed between the LAN’s. 
Upon power up, the Ethernet interface’s MAC filtering table can become corrupted, and must 
be reset, or allowed to timeout.  After power up, press the reset button on the back of the 
FreeWave Ethernet, or allow 4.5 minutes to pass and the table to reset. 

 

 

The LINK LED is off: 
The Modem has not successfully connected to the LAN. 
Make sure that the Modem is powered On. 
Make sure that the Ethernet device connected to the Modem is On. 
Make sure the Modem and the Ethernet device are connected with a good Ethernet cable. 
Try switching the "Normal/Crossover" switch to the opposite position. 
Ensure the Ethernet device is set for auto-detect, or 10BaseT.  

 

 

The TX LED stays on: 
Data is not successfully going from this modem's LAN to the other modem's LAN. 
Make sure the radio link is working (see Main Manual). 
Make sure both modems are linked to their respective LANs (modems' LINK LED’s are on). 

 

 

The RX LED stays on: 
Data isn't going between this modem and its LAN. 
The Ethernet device to which this modem is connected isn't receiving data. 

 

 

The COL LED flashes: 
There are collisions on this modem's LAN. 
Collisions are normal when the modem is connected to the LAN is through a hub (it simply 
means that two Ethernet devices tried to send data through the hub at the same time).  The 
Ethernet network is designed handle such collisions. 
Collisions do not happen when the modem is connected directly through a switch, a NIC, or a 
router. 

 

 

The ERR LED flashes: 
A data buffer is getting full. 
This typically occurs if the radio settings are incorrect.  This also occurs when the radio link, 
or the LAN link are not present.  Check the radio settings, the Radio Link, and the LAN link. 
Try pressing the Reset button on the back panel to reset the Ethernet Interface. 

LAD0013AB Rev H 

10 of 11 

Summary of Contents for HT-900 Series

Page 1: ...IES HIGH THROUGHPUT ETHERNET BRIDGE Addendum to the FreeWave Manual V1 0h Firmware Release Version 7 60 FreeWave Technologies Inc 1880 S Flatiron Ct Suite F Boulder CO 80301 303 444 3862 LAD0013AB Rev...

Page 2: ...ack Panel 4 Front Panel 5 Setup 6 Setup Menus 6 Menu 1 6 Menu 1 Submenu F 6 Menu 2 7 Menu 3 for Point to Point 7 Menu 3 for Point to Multipoint 7 Menu 5 for Point to Multipoint 7 Errata for Firmware V...

Page 3: ...to conserve the available bandwidth the FreeWave HT Ethernet Modems have a MAC address filter Each packet received by the Ethernet interface from the LAN is checked for the destination MAC address aga...

Page 4: ...reeWave LAN RJ45 connector for Ethernet 10Base T network NORMAL CROSSOVER Switches the RJ45 connector from normal wiring to crossover wiring to avoid the need for a crossover cable POWER 2 1 mm coaxia...

Page 5: ...other LED s on the top row show the activity of the Ethernet port The TX and RX LED s in the top row show the activity between the Ethernet Interface and the Radio Modem The LED s on the bottom row s...

Page 6: ...arity 0 Must be 0 Default B MODBus RTU 0 Must be 0 Disabled C RS232 485 0 Must be 0 TTL D Setup Port 2 Must be 2 Diagnostics port used for Set up E TurnOffDelay 0 TurnOnDelay 0 No effect 0 Default for...

Page 7: ...commended 9 for Asymmetric Data 2 Min Packet Size 1 Recommended 1 for Asymmetric Data 3 Xmit Rate 1 4 RF Data Rate 3 Must use 3 for Multipoint networks B Delay 0 70 0 Option not available in Multipoin...

Page 8: ...supported Only 3 Frequency tables are available 0 1 and 2 Serial Slave UDP mode is not Supported The Following are known issues with Firmware version 2 55 Overall Point to Point and Point to Multipoin...

Page 9: ...ters Point to Multipoint Functionality Delay Option is not functional Data Rate of 2 is not supported Improvements Radio lock up issue in networks with repeaters was resolved The following are known i...

Page 10: ...that the Ethernet device connected to the Modem is On Make sure the Modem and the Ethernet device are connected with a good Ethernet cable Try switching the Normal Crossover switch to the opposite pos...

Page 11: ...en FreeWave radios LAN Local Area Network A computer network such as Ethernet Collision The condition when one LAN device tries to transmit while another device is already transmitting NIC Network Int...

Reviews: