![Freescale Semiconductor MCF51CN128 Reference Manual Download Page 27](http://html1.mh-extra.com/html/freescale-semiconductor/mcf51cn128/mcf51cn128_reference-manual_2330646027.webp)
Chapter 4
System Setup
4.1 Getting Started
This section describes the using the software and hardware to demonstrate the use of this
reference design
4.2 Install Software
This is the process to download firmware to hardware:
• Connect the BDM Multilink or BDM Cyclone PRO to the MCF51CN128 reference
design hardware.
• Download software using CodeWarrior 6.2.1v compiler.
• Disconnect the BDM Multilink or BDM Cyclone PRO from the programmed target.
Before downloading the firmware to the MCF51CN128 reference design hardware, the
M51CN128RD C-macro must be selected. The file name is m51cn128evb.h.
Figure 4-1. Selection of the MCF51CN128 reference design hardware
4.3 Hardware Setup
For hardware setup, perform the following steps:
1. The power supply must be between 3.7 and 5.5 V because of regulator limits. To select
a different power source, go to .
2. The red LED near the RJ45 connector must be turned on as soon as the power is applied.
TCP/IP Applications Using the MCF51CN Family—Designer Reference Manual, Rev. 0, 12/2009
27
Freescale Semiconductor