background image

Voltage Supply

MC33794 Touch Panel System, Rev. 1.0

Freescale Semiconductor

4

VOLTAGE SUPPLY

The first step is to prepare the Analyzer Board by plugging the 9V battery or connecting an external 9V source to the Jack 

“P1”, when connecting battery and external supply at the same time, the external power supply jack will disconnect the battery 
VCC terminal.

For powering Analyzer Board make 
sure power supply, either battery or 
external power supply doesn’t exceed 
15V.Place a common 9 volts battery 
on the battery holder with the 
appropriate polarity, or c9V 
center positive on the jack for external 
power supply and then move “S1” to 
the “ON” position.

With the default firmware up into the 
microcontroller and the default 
settings described above, the 
application should be running; LED’s, 
7 segments displays and audio 
transducer will provide feedback as 
the system detects a pressed 
condition within the touch pads.

PROGRAMMING SETTINGS

PROGRAMMING THROUGH SERIAL BOOTLOADER TOOL

When running the loaded program in the demo, the USER/MON08 switch “S2” should be on the USER position; USER mode is 
also used when programming the microcontroller using the serial bootloader tool.

To download the firmware using the bootloader tool:

1. Make sure all the required programs are available in the programmer PC, you must have the *.S19 file to be downloaded 

into the MCU, TeraTerm software used for serial communications, and the required bootloader already programmed into 
the demo board MCU. 

2. Open and configure TeraTerm software, a new connection window will appear, select on the same window “Serial”, select 

the serial port available at your computer and then press the [OK] button.

On/Off Switch

Summary of Contents for MC33794

Page 1: ...C33794SIUG User s Guide Rev 1 0 09 2005 MC33794 Touch Panel System Using E Field Sensor Setup Instructions Reference Design Documentation for RDMC33794 This document contains information on a new prod...

Page 2: ...gn Reference manual for RDMC33794 Application note AN1985 Touch Panel Applications using The MC33794 E field IC CONVENTIONS This document uses the following conventions Term or Value Definition Exampl...

Page 3: ...icrocontroller s AD channel is feed directly from the MC33794 output pin LEVEL or if the output signal is first amplified by the on board op amp with adjustments in offset and amplitude and then feed...

Page 4: ...d above the application should be running LED s 7 segments displays and audio transducer will provide feedback as the system detects a pressed condition within the touch pads PROGRAMMING SETTINGS PROG...

Page 5: ...uld appear use the TeraTerm File Send File option to send the S19 file a progress dialog will show up 8 Once the code is downloaded the p rogram w ipe e x it message will appear again press x and the...

Page 6: ...the MCU Flash will be programmed 5 the following message should appear press yes button to program flash memory 6 Once the flash programming process is finished unplug the MONO8 connector and set the...

Page 7: ...p_Level Amplifier stage output MC33794 s output with adjustment in offset and amplitude Jumper name Functional description JP1 Position 1 2 Connects microcontroller A D input channel 3 to E field outp...

Page 8: ...of its products for any particular purpose nor does Freescale Semiconductor assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all...

Reviews: