![Freedom Won Lite Commercial 100/80 HV Installation And User Manual Download Page 6](http://html1.mh-extra.com/html/freedom-won/lite-commercial-100-80-hv/lite-commercial-100-80-hv_installation-and-user-manual_2329981006.webp)
Freedom Lite Commercial Installation Manual Revision 3
P a g e
5 | 29
The DC cables exit the unit through glands located near the
top of the right hand side
of the
casing (as in Fig 2.1) for the 100/70 and 120/84 models, and
near the right side of the top
of
the casing for the rest of the 52V range (as in Figure 2.2).
Fig 2.2 Top Cable Exit Example on a Lite Commercial 200/140
The DC cables per pole vary in number and size across these models [three in Figure 2.1 for
example]. The correct cable lugs for connecting these leads to the inverter must be in hand
when doing an installation. If there are several inverters and charge controllers that need to
be connected to the battery it is advisable to install a DC connector box to use as a junction
point from which to branch out to all the battery connected equipment. Note that the
cables are provided 3m long as standard and up to 5m long can be ordered at extra cost.
Note that the HV and HV+ models have bottom exit cables that exit on the bottom right
hand end of the battery as in Fig 2.3.