![Freedom Won LiTE Business 40/32 Installation Manual Download Page 18](http://html1.mh-extra.com/html/freedom-won/lite-business-40-32/lite-business-40-32_installation-manual_2329979018.webp)
Freedom LiTE Installation Manual Revision 14
P a g e
17 | 30
Fig 4.2 Pin Configuration for standard Type T-568B RJ45 plug
Table 5.2 Inverter End Pin Configuration for CAN Bus Control Cable for some supported
inverters
–
for further information refer to the Freedom LiTE and eTower Interfacing Guide.
Inverter Brand
CAN L
CAN H
Comments
Axpert / Kodak: King, Max and
VMIII
Requires a CAN Bus to RS485
converter that is available from
Freedom Won. Enquire from
Goodwe: ES
Pin 5
(blue/white)
Pin 1
(orange/white)
LiTE to Type 1 RJ45 cable required
for connecting CAN Bus from LiTE to
Goodwe
–
available from Freedom
Won. Enquire from
Growatt / Sunforce: 5kW
Pin 4 (Blue)
Pin 5
(Blue/white)
LiTE to Type 1 RJ45 Cable required
for connecting CAN Bus from LiTE to
inverter, available from freedom
won. Enquire from
Imeon: 3.6 and 9.12
Pin 2 (orange)
Pin 1
(orange/white)
Type Imeon RJ45 cable required for
connecting CAN Bus from LiTE to
inverter
–
available from Freedom
Won. Enquire from
Ingeteam: Ingecon Sun, Storage
1Play, 3TL and 6TL
Open terminal
Open terminal
Labelled on inverter
Koyoe: 3kVA Hybrid
Please connect Freedom Won if you
need to connect on of these
inverters to a LiTE
MLT: PowerStar 10, Oasis,
Nomad MPPT
Pin 5
(blue/white)
Pin 4 (blue)
The MLT range of products offers
complete CAN Bus interfacing.
PowerStar 10 and Oasis
–
use a LiTE
to Type 1 RJ45 Ethernet cable
–
available from Freedom Won.
Nomad
–
a CAN terminal plug is
provided on the PC board of the
Nomad with a resistor that can be
enabled with a bridge. Please see
Nomad manual.
Revo: 5kVA
Pin 5
(blue/white)
Pin 4 (blue)
Requires Type 1 CAN Bus cable
–
available from Freedom Won.