background image

|

 

P a g e

 

Rev 11.2016 

General Information 

 

Note:

 All tubs need to be leveled in its final resting position and have all feet touching 

the ground. 

It is advised to have tub onsite before preparing drain location. 

Manufacturer reserves the right to change specs or features at any time. 

Notice to Installers 

 

THE FLEXIBLE DRAIN HOSE THAT IS INCLUDED WITH THIS UNIT IS FOR INSTALLATION 
INTO AN OPEN FLOOR DRAIN ONLY. SUBSTITUTING THE EXISTING DRAIN SHOE FOR A 
DIFFERENT ONE WILL NOT VOID THE WARRANTY AS LONG AS THERE NO DAMAGE OR 
EVIDENCE OF MISUSE TO THE BASE 

 
Electrical Parameters 
 

Rated Voltage  Frequency 

Motor Power 

Voltage of 

Control Circuit 

 

110V~120v 

60HZ 

0.745KW(1HP)/1.0KW 

5.5-6.5 Amps 

DC12V 

 

 

Electrical Requirements 

 

1 dedicated 10-2 line for water pump (line 1, ground  and neutral) 

110 volt, 30 amp GFCI breaker 

There is a length of wire supplied to connect to power source 
      

Plumbing Requirements 
 

The unit is equipped with hot and cold, metal braided ½ inch water supply hose with 
½ national pipe thread.  

Need to install accessible hot and cold shutoffs with ½ -male national pipe thread 
(not included). 

Supply hoses are to connect from the manifold on the unit to the shutoff valves. 

All water jet features are pre plumbed with reinforced braided flexible supply hose 

All fixtures and fittings should be checked for tightness as they may have come loose 
during transport. Access panel area advised. 

 

Tub Installation 

 

A. Water Head: One cold water supply pipe, one hot water supply pipe. 
B. Drainage: The diameter of the drain should be (greater than or equal to) 40mm. This 

drainage can be at a distance of 300-400mm from the location we show on the chart. 
 

Summary of Contents for Chelsea APWMG015

Page 1: ...M G014 Installation Manual Chelsea Massage Bathtub Model APWMG015 ...

Page 2: ...al Information 1 Notice to Installers 1 Electrical Parameters 1 Electrical Requirements 1 Plumbing Requirements 1 Tub Installation 1 Installation of Drain 2 Operation of Bathtub 3 Troubleshooting 3 Cleaning and Maintenance 4 ...

Page 3: ...s 1 dedicated 10 2 line for water pump line 1 ground and neutral 110 volt 30 amp GFCI breaker There is a length of wire supplied to connect to power source Plumbing Requirements The unit is equipped with hot and cold metal braided inch water supply hose with national pipe thread Need to install accessible hot and cold shutoffs with male national pipe thread not included Supply hoses are to connect...

Page 4: ...t so the water will drain completely from the tub All feet need to be touching the floor and tub needs to be level 2 Install the hand held spray wand and the headrests 3 Carefully ground the bathtub Installation of Drain Below is a diagram if flexible hose is used Floor drain must have trap installed ...

Page 5: ...r when it reaches the water level Water pump valve controls the whirlpool massage pump and jets 1 Drain water for about 10 minutes after installation to clear drain lines and test for water leaks 2 After using shut off water and power supply Troubleshooting Trouble Reason Solution No Power Supply 1 Power plug is not connected to the socket 2 Circuit breaker is not on 1 Tightly connect the plug wit...

Page 6: ...cratches or stains with 2000 sand paper and then polish with polishing wax 5 If water is hard it is suggested to clean the massage the device twice a year according to this following method a Feed 40 C warm water into the bathtub until it reaches the lowest water level b Mix 2g of liquid detergent for every liter of water pour in and start the water force massage device and allow it to run for abo...

Reviews: