2-10
Note:
If your DLT-VS80 Internal Drive is attached to a narrow SCSI bus, only IDs 0 through
7 are valid.
Locate the SCSI ID jumpers on the rear panel of the drive as shown in Figure 2-5.
Figure 2-5: SCSI ID Jumper Block Location
To set the SCSI ID on your DLT-VS80 Internal Drive, use the supplied jumpers to select the
desired SCSI ID as shown in the following table:
SCSI
ID
0 1 2 3 4 5* 6 7
Jumper
Block
SCSI
ID
8 9 10 11 12 13 14 15
Jumper
Block
Table 1: Setting the SCSI ID Jumper Block
* Factory default SCSI ID
2.4.3.2
When to Use Termination
If your DLT-VS80 Internal Drive is the only SCSI device – other than the SCSI host adapter
– on the selected server or workstation's SCSI bus, it must be terminated. Likewise, if your
DLT-VS80 Internal Drive is the last SCSI device on the selected server or workstation’s
SCSI bus, it must be terminated.
SCSI ID Jumpers
68-pin high-density
SCSI Connector
Power Connector