![Freecom FC TapeWare AIT-250i FC Specification Download Page 70](http://html.mh-extra.com/html/freecom/fc-tapeware-ait-250i-fc/fc-tapeware-ait-250i-fc_specification_2329662070.webp)
6.Command Specification
LOG SENSE
6-18
SONY AIT-E Turbo drive SDX-250V series Ver.1.0
6.6.6. Tape Log Page (Sony Unique)
This page is a Sony unique page which provides information on the tape currently being used. This log cannot be
cleared and has the following format:
Table 6-20: Tape Log Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (30h)
1
Reserved
2
(MSB)
Page Length (58h)
3
(LSB)
4
(MSB) Parameter
Code
5
6
DU (0)
DS (1)
TSD (0)
ETC (0)
TMC (00)
Reserved
LP (0)
7
Parameter Length (m)
8
Parameter
Value
3+m
This page is used to return Tape Log information to the host in a format which conforms to the LOG SENSE
command page format.
Supported Parameter Codes in this page are listed below along with their meanings:
Table 6-21: Tape Log parameter codes
Parameter Code
Description
Description
001h
002h
003h
004h
005h
006h
007h
008h
009h
00Ah
00Bh
00Ch
00Dh
Current number of Groups Written
Current number of RAW Retries
Current number of Groups Read
Current number of ECC-3 Retries
Previous number of Groups Written
Previous number of RAW Retries
Previous number of Groups Read
Previous number of ECC-3 Retries
Total number of Groups Written
Total number of RAW Retries
Total number of Groups Read
Total number of ECC-3 Retries
Load Count
3
2
3
2
3
2
3
2
4
3
4
3
2
This information is contained within RAM in the Drive Controller. When a cassette is loaded, the contents of the
System Area are copied into this log. The log is updated as the tape is used and is copied back onto the System
Area when the cassette is unloaded (if the tape is Write enabled).
Note:
The System Area only contains 'previous' and 'total' information - (when the cassette is unloaded, the 'current'
values become the System Area 'previous' values).
The term 'current' refers to information generated during the current load of the tape; 'previous' refers to information
generated during the last tape load; 'total' refers to information generated during the life of the tape since it was first
initialized including the current load.