LOG SENSE
6.Command Specification
SONY AIT-E Turbo drive SDX-250V series Ver.1.0
6-17
Table 6-15: Error Counter parameter codes
Parameter
Code
Description
Parameter
Length
(Bytes)
Default
Cumulative
Default
Threshold
0003h
Total Errors Corrected (Soft Errors)
2
0
FFFFh
0004h
Total Times Correction
4
0
FFFFFFFFh
0005h
Total Groups Processed (Algorithm
Processed)
4 0
FFFFFFFFh
0006h
Total Errors Uncorrected (Hard Errors)
2
0
FFFFh
6.6.5. Last N Error Events List
This page is used to report information on soft and hard errors encountered by the device during normal operation.
Each parameter corresponds to an encountered error and is a report of what type of error occurred and when it
occurred. The format of the page is given below:
Table 6-16: Last N Error Events Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (07h)
1
Reserved
2
(MSB)
Page Length (n*14)
3
(LSB)
4
(MSB) Parameter
Code
5
(LSB)
6
DU (0)
DS (1)
TSD (0)
ETC (0)
TMC (00)
Reserved
LP
(1)
7
Parameter Length (0Ah)
8
Parameter
Value
17
The Parameter Codes supported are 1 through 30 where 30 is the maximum number of entries in the log page.
If there are no entries, the command will return the Page Header with the Page Length field set to ZERO.
Each error event record contains diagnostic information for a single error encountered by the device. The parameter
codes associated with the error-event records indicate the order in which the errors occurred. A higher parameter
code indicates that the error event occurred later in time.
Each parameter entry is 10 bytes long and has the following format:
Table 6-17: Error Event format
Byte Offset
Meaning
0–4
5
6–9
Result Message (see Diagnostic Clause)
Unused
Time-stamp (number of 1 minute increments since power-on)
When the log page becomes full, no more entries will be added until the log is cleared (using one of the methods
described previously) or a reset occurs. The current cumulative values will be returned regardless of the page
control field in the LOG SENSE CDB.