C o n f i g u r e a t i o n   G u i d e

MODBUS RTU

L1_THD_V: 40610

This address contains the measured THD of voltage on phase 1, expressed in %

L2_THD_V: 40612

This address contains the measured THD of voltage on phase 2, expressed in %

L3_THD_V: 40614

This address contains the measured THD of voltage on phase 3, expressed in %

L1_Iac: 40620

This address contains the measured RMS current on phase 1, expressed in A

L2_Iac: 40622

This address contains the measured RMS current on phase 2, expressed in A

L3_Iac: 40624

This address contains the measured RMS current on phase 3, expressed in A

L1_THD_I: 40626

This address contains the measured THD of charging current on phase 1, expressed in %

L2_THD_I: 40628

This address contains the measured THD of charging current on phase 2, expressed in %

L3_THD_I: 40630

This address contains the measured THD of charging current on phase 3, expressed in %

Summary of Contents for eProWallbox Series

Page 1: ...EN C o n f i g u r a t i o n G u i d e MODBUS RTU ...

Page 2: ...2 C o n f i g u r e a t i o n G u i d e MODBUS RTU TABLE OF CONTENT INTRODUCTION 3 CONFIGURATION 3 LIST OF CHARGING STATION REGISTERS 4 ADDRESS DESCRIPTION 6 ...

Page 3: ...sidered as a Master while the charging station will be considered as a Slave The data are sent via RTU On the charging station are present two RS485 communication ports to be used for a Daisy Chain connection The communication shall be established between the wallbox and a PC using a USB to RS422 RS485 Serial Port Adapter Cable according to the following scheme for connection The following documen...

Page 4: ...R xx yy zz MDBUS_VERSION 40012 4 ASCII R HW_TYPE 40016 1 UINT16 R 1 DEVICE_TYPE 40017 1 UINT16 R 1 HW_CURRENT_LIMIT 40018 2 UINT32 R mA ACTUAL_ERROR 40100 1 UINT16 R GENERAL_STATUS 40101 1 UINT16 R OCPP_STATUS 40102 1 UINT16 R USER_CURRENT_LIMIT 40103 2 UINT32 R mA LOAD_UNBALANCE_LIMITING 40106 1 UINT16 R DPM_LIMITING 40107 1 UINT16 R TEMP_DERATING_STAUTS 40108 1 UINT16 R RTU_ADR 40200 1 UINT16 R ...

Page 5: ...LOAT_IEEE754 R Varh L2_REACTIVE_ENERGY 40666 2 FLOAT_IEEE754 R Varh L3_REACTIVE_ENERGY 40668 2 FLOAT_IEEE754 R Varh REGISTER START ADDRESS SIZE TYPE R W DEFAULT VALUE UNIT SERIAL_NUMBER 40000 8 ASCII R 0123456789ABCDEF SW_VERSION 40008 4 ASCII R xx yy zz MDBUS_VERSION 40012 4 ASCII R HW_TYPE 40016 1 UINT16 R 1 DEVICE_TYPE 40017 1 UINT16 R 1 HW_CURRENT_LIMIT 40018 2 UINT32 R mA ACTUAL_ERROR 40100 1...

Page 6: ...oftware or firmware of the charging station MDBUS_VERSION 40012 The address contains the revision of the Modbus map HW_TYPE 40016 tbd DEVICE_TYPE 40017 The address indicates the electrical connection of the charging station 0 AC 1 phase 1 AC 3 phase HW_CURRENT_LIMIT 40018 The address contains the Current Limit measured in mA according to the specific position of the Rotary Switch ACTUAL_ERROR 4010...

Page 7: ... OCPP_Status A 1 Preparing OCPP_Status B 2 Charging OCPP_Status C 3 SuspendedEV OCPP_Status D 4 SuspendedEVSE OCPP_Status E 5 Finishing OCPP_Status F 6 Reserved OCPP_Status G 7 Unavailable OCPP_Status H 8 Faulted OCPP_Status I USER_CURRENT_LIMIT 40103 The address contains the Current Limit set by the user through the App expressed in mA LOAD_UNBALANCE_LIMITING 40106 The address contains the status...

Page 8: ...in overtemperature The function is enabled when the temperature overcomes 85 C RTU_ADR 40200 The address contains the current charging station Modbus Bus address which is between 1 and 32 The default value is set to 1 NEW_RTU_ADR 40201 The address is used for setting the new Modbus Bus address Insert in this field the new value that will identify the charging station The default value is set to 1 ...

Page 9: ...sed for setting the new Baud Rate value Insert in this field the new Baud Rate value The default value is set to 4 ACTIVATE_NEW_BAUD_RATE 40212 The address is used for the activation of a new Baud Rate value Enter 0x5555 to activate the new Baud Rate value inserted in the address 40211 DPM_ENABLED 40400 The address contains the status of the DPM 0 disabled 1 enabled MID_METER_ENABLED 40401 The add...

Page 10: ...used to set the current for the load unbalance function It contains the maximum allowable current unbalance between the phases This function is enabled only if the wallbox is connected in three phase configuration The default value is set to 32000 mA To modify this parameter you can connect to the wallbox following the procedure described in this manual in the Configuration chapter 1 Enter the Set...

Page 11: ...nother meter external from the charging station is installed 0 External Meter 1 Internal Meter WATCHDOG_TIMER_ENABLED 40412 With this register is possible to enable the load unbalance and fallback current functions 0 Watchdog timer disabled functions disabled 1 Watchdog timer enabled functions enabled with the following default logic A 600 s timer will start If in the 600 s the reset signal Addres...

Page 12: ... activate SET_DEFAULT_VALUE 40503 The address is used to reset the charging station parameters to default values CHARGE_TIME 40600 The address contains the time of the charging session expressed in s TEMPERATURE 40602 The address contains the temperature value at which the charging station is operating expres sed in K L1_Vac 40604 This address contains the measured RMS voltage on phase 1 expressed...

Page 13: ...is address contains the measured RMS current on phase 1 expressed in A L2_Iac 40622 This address contains the measured RMS current on phase 2 expressed in A L3_Iac 40624 This address contains the measured RMS current on phase 3 expressed in A L1_THD_I 40626 This address contains the measured THD of charging current on phase 1 expressed in L2_THD_I 40628 This address contains the measured THD of ch...

Page 14: ...ss contains the Reactive Power value measured on phase 1 expressed in VAr L2_Qac 40644 This address contains the Reactive Power value measured on phase 2 expressed in VAr L3_Qac 40646 This address contains the Reactive Power value measured on phase 3 expressed in VAr L1_Sac 40648 This address contains the Apparent Power value measured on phase 1 expressed in VA L2_Sac 40650 This address contains t...

Page 15: ...ressed in Wh L3_ACTIVE_ENERGY 40662 This address contains the Active Energy value measured on phase 3 expressed in Wh L1_REACTIVE_ENERGY 40664 This address contains the Reactive Energy value measured on phase 1 expressed in Varh L2_REACTIVE_ENERGY 40666 This address contains the Reactive Energy value measured on phase 2 expressed in Varh L3_REACTIVE_ENERGY 40668 This address contains the Reactive ...