Free2Move eSolutions eProWallbox Series Configuration Manual Download Page 4

4

C o n f i g u r e a t i o n   G u i d e

MODBUS RTU

Once the connection is completed and the communication is established, follow the steps:

1. 

Open the service tool for PC provided by Free2Move eSolutions

2. 

Select the serial port COM4 by inserting 1

3. 

Select the BaudRate 115200 by inserting 4

4. 

Select the UnitAddress by inserting 1

5. 

The page displayed contains all the accessible sections with useful information 
on the wallbox

The power supply of the device must remain switched off throughout 
this phase.
Failure to comply with these instructions can lead to serious damage 
to persons and property, including death.

LIST OF CHARGING STATION REGISTERS

REGISTER

 

START 

ADDRESS

 

SIZE 

TYPE 

R/W 

DEFAULT VALUE

 

UNIT 

SERIAL_NUMBER

40000

8

ASCII

R

0123456789ABCDEF

-

SW_VERSION

40008

4

ASCII

R

xx.yy.zz

-

MDBUS_VERSION

40012

4

ASCII

R

-

HW_TYPE

40016

1

UINT16

R

1

-

DEVICE_TYPE

40017

1

UINT16

R

1

-

HW_CURRENT_LIMIT

40018

2

UINT32

R

-

mA

ACTUAL_ERROR

40100

1

UINT16

R

-

-

GENERAL_STATUS

40101

1

UINT16

R

-

-

OCPP_STATUS

40102

1

UINT16

R

-

-

USER_CURRENT_LIMIT

40103

2

UINT32

R

-

mA

LOAD_UNBALANCE_LIMITING

40106

1

UINT16

R

-

-

DPM_LIMITING

40107

1

UINT16

R

-

-

TEMP_DERATING_STAUTS

40108

1

UINT16

R

-

-

RTU_ADR

40200

1

UINT16

R

1

-

NEW_RTU_ADR

40201

1

UINT16

R/W

1

-

ACTIVATE_NEW_RTU_ADR

40202

1

UINT16

W

-

-

BAUD_RATE

40210

1

UINT16

R

4

-

NEW_BAUD_RATE

40211

1

UINT16

R/W

4

-

ACTIVATE_NEW_BAUD_RATE

40212

1

UINT16

W

-

-

DPM_ENABLED

40400

1

UINT16

R/W

0

-

MID_METER_ENABLED

40401

1

UINT16

R/W

0

-

LOAD_UNBALANCE_ENABLED

40402

1

UINT16

R/W

0

-

LOAD_UNBALANCE_CURRENT

40403

2

UINT32

R/W

32000

mA

ON_OFF_INPUT

40406

1

UINT16

R/W

1

-

CURRENT_LIMIT

40407

2

UINT32

R/W

32000

mA

FALLBACK_CURRENT

40409

2

UINT32

R/W

32000

mA

METER_USED

40411

1

UINT16

R/W

1

-

WATCHDOG_TIMER_ENABLED

40412

1

UINT16

R/W

1

-

WATCHDOG_TIMER

40413

1

UINT16

R/W

600

s

RESET_LAST_ERRORS

40500

1

UINT16

W

-

-

RESET_ENERGY

40501

1

UINT16

W

-

-

RESET_WTCH_DOG

40502

1

UINT16

W

-

-

SET_DEFAULT_VALUE

40503

1

UINT16

W

-

-

s

CHARGE_TIME

40600

2

UINT32

R

-

TEMPERATURE

40602

2

FLOAT_IEEE754

R

-

K

L1_Vac

40604

2

FLOAT_IEEE754

R

-

V

L2_Vac

40606

2

FLOAT_IEEE754

R

-

V

L3_Vac

40608

2

FLOAT_IEEE754

R

-

V

L1_THD_V

40610

2

FLOAT_IEEE754

R

-

%

L2_THD_V

40612

2

FLOAT_IEEE754

R

-

%

L3_THD_V

40614

2

FLOAT_IEEE754

R

  

%

L1_Iac

40620

2

FLOAT_IEEE754

R

-

A

L2_Iac

40622

2

FLOAT_IEEE754

R

-

A

L3_Iac

40624

2

FLOAT_IEEE754

R

-

A

L1_THD_I

40626

2

FLOAT_IEEE754

R

 

%

L2_THD_I

40628

2

FLOAT_IEEE754

R

 

%

L3_THD_I

40630

2

FLOAT_IEEE754

R

 

%

L1_Pac

40636

2

FLOAT_IEEE754

R

-

W

L2_Pac

40638

2

FLOAT_IEEE754

R

-

W

L3_Pac

40640

2

FLOAT_IEEE754

R

-

W

L1_Qac

40642

2

FLOAT_IEEE754

R

 

Var

L2_Qac

40644

2

FLOAT_IEEE754

R

 

Var

L3_Qac

40646

2

FLOAT_IEEE754

R

 

Var

L1_Sac

40648

2

FLOAT_IEEE754

R

 

VA

L2_Sac

40650

2

FLOAT_IEEE754

R

 

VA

L3_Sac

40652

2

FLOAT_IEEE754

R

 

VA

L1_ACTIVE_ENERGY

40658

2

FLOAT_IEEE754

R

-

Wh

L2_ACTIVE_ENERGY

40660

2

FLOAT_IEEE754

R

 

Wh

L3_ACTIVE_ENERGY

40662

2

FLOAT_IEEE754

R

 

Wh

L1_REACTIVE_ENERGY

40664

2

FLOAT_IEEE754

R

 

Varh

L2_REACTIVE_ENERGY

40666

2

FLOAT_IEEE754

R

 

Varh

L3_REACTIVE_ENERGY

40668

2

FLOAT_IEEE754

R

 

Varh

Summary of Contents for eProWallbox Series

Page 1: ...EN C o n f i g u r a t i o n G u i d e MODBUS RTU ...

Page 2: ...2 C o n f i g u r e a t i o n G u i d e MODBUS RTU TABLE OF CONTENT INTRODUCTION 3 CONFIGURATION 3 LIST OF CHARGING STATION REGISTERS 4 ADDRESS DESCRIPTION 6 ...

Page 3: ...sidered as a Master while the charging station will be considered as a Slave The data are sent via RTU On the charging station are present two RS485 communication ports to be used for a Daisy Chain connection The communication shall be established between the wallbox and a PC using a USB to RS422 RS485 Serial Port Adapter Cable according to the following scheme for connection The following documen...

Page 4: ...R xx yy zz MDBUS_VERSION 40012 4 ASCII R HW_TYPE 40016 1 UINT16 R 1 DEVICE_TYPE 40017 1 UINT16 R 1 HW_CURRENT_LIMIT 40018 2 UINT32 R mA ACTUAL_ERROR 40100 1 UINT16 R GENERAL_STATUS 40101 1 UINT16 R OCPP_STATUS 40102 1 UINT16 R USER_CURRENT_LIMIT 40103 2 UINT32 R mA LOAD_UNBALANCE_LIMITING 40106 1 UINT16 R DPM_LIMITING 40107 1 UINT16 R TEMP_DERATING_STAUTS 40108 1 UINT16 R RTU_ADR 40200 1 UINT16 R ...

Page 5: ...LOAT_IEEE754 R Varh L2_REACTIVE_ENERGY 40666 2 FLOAT_IEEE754 R Varh L3_REACTIVE_ENERGY 40668 2 FLOAT_IEEE754 R Varh REGISTER START ADDRESS SIZE TYPE R W DEFAULT VALUE UNIT SERIAL_NUMBER 40000 8 ASCII R 0123456789ABCDEF SW_VERSION 40008 4 ASCII R xx yy zz MDBUS_VERSION 40012 4 ASCII R HW_TYPE 40016 1 UINT16 R 1 DEVICE_TYPE 40017 1 UINT16 R 1 HW_CURRENT_LIMIT 40018 2 UINT32 R mA ACTUAL_ERROR 40100 1...

Page 6: ...oftware or firmware of the charging station MDBUS_VERSION 40012 The address contains the revision of the Modbus map HW_TYPE 40016 tbd DEVICE_TYPE 40017 The address indicates the electrical connection of the charging station 0 AC 1 phase 1 AC 3 phase HW_CURRENT_LIMIT 40018 The address contains the Current Limit measured in mA according to the specific position of the Rotary Switch ACTUAL_ERROR 4010...

Page 7: ... OCPP_Status A 1 Preparing OCPP_Status B 2 Charging OCPP_Status C 3 SuspendedEV OCPP_Status D 4 SuspendedEVSE OCPP_Status E 5 Finishing OCPP_Status F 6 Reserved OCPP_Status G 7 Unavailable OCPP_Status H 8 Faulted OCPP_Status I USER_CURRENT_LIMIT 40103 The address contains the Current Limit set by the user through the App expressed in mA LOAD_UNBALANCE_LIMITING 40106 The address contains the status...

Page 8: ...in overtemperature The function is enabled when the temperature overcomes 85 C RTU_ADR 40200 The address contains the current charging station Modbus Bus address which is between 1 and 32 The default value is set to 1 NEW_RTU_ADR 40201 The address is used for setting the new Modbus Bus address Insert in this field the new value that will identify the charging station The default value is set to 1 ...

Page 9: ...sed for setting the new Baud Rate value Insert in this field the new Baud Rate value The default value is set to 4 ACTIVATE_NEW_BAUD_RATE 40212 The address is used for the activation of a new Baud Rate value Enter 0x5555 to activate the new Baud Rate value inserted in the address 40211 DPM_ENABLED 40400 The address contains the status of the DPM 0 disabled 1 enabled MID_METER_ENABLED 40401 The add...

Page 10: ...used to set the current for the load unbalance function It contains the maximum allowable current unbalance between the phases This function is enabled only if the wallbox is connected in three phase configuration The default value is set to 32000 mA To modify this parameter you can connect to the wallbox following the procedure described in this manual in the Configuration chapter 1 Enter the Set...

Page 11: ...nother meter external from the charging station is installed 0 External Meter 1 Internal Meter WATCHDOG_TIMER_ENABLED 40412 With this register is possible to enable the load unbalance and fallback current functions 0 Watchdog timer disabled functions disabled 1 Watchdog timer enabled functions enabled with the following default logic A 600 s timer will start If in the 600 s the reset signal Addres...

Page 12: ... activate SET_DEFAULT_VALUE 40503 The address is used to reset the charging station parameters to default values CHARGE_TIME 40600 The address contains the time of the charging session expressed in s TEMPERATURE 40602 The address contains the temperature value at which the charging station is operating expres sed in K L1_Vac 40604 This address contains the measured RMS voltage on phase 1 expressed...

Page 13: ...is address contains the measured RMS current on phase 1 expressed in A L2_Iac 40622 This address contains the measured RMS current on phase 2 expressed in A L3_Iac 40624 This address contains the measured RMS current on phase 3 expressed in A L1_THD_I 40626 This address contains the measured THD of charging current on phase 1 expressed in L2_THD_I 40628 This address contains the measured THD of ch...

Page 14: ...ss contains the Reactive Power value measured on phase 1 expressed in VAr L2_Qac 40644 This address contains the Reactive Power value measured on phase 2 expressed in VAr L3_Qac 40646 This address contains the Reactive Power value measured on phase 3 expressed in VAr L1_Sac 40648 This address contains the Apparent Power value measured on phase 1 expressed in VA L2_Sac 40650 This address contains t...

Page 15: ...ressed in Wh L3_ACTIVE_ENERGY 40662 This address contains the Active Energy value measured on phase 3 expressed in Wh L1_REACTIVE_ENERGY 40664 This address contains the Reactive Energy value measured on phase 1 expressed in Varh L2_REACTIVE_ENERGY 40666 This address contains the Reactive Energy value measured on phase 2 expressed in Varh L3_REACTIVE_ENERGY 40668 This address contains the Reactive ...

Page 16: ...16 C o n f i g u r e a t i o n G u i d e MODBUS RTU Registered office Free2move eSolutions S p A Piazzale Lodi 3 20137 Milan Italy esolutions free2move com ...

Reviews: