Nature of trouble
Possible cause
Service
Pump operates intermittently.
Normal when weather changes.
None.
Sensors connected to wrong
terminals.
Check sensor connections - Refer to
controller manual “Installation” section.
Improper system “switch-on” or
“switch-off” temperature.
Check sensor resistance - Refer to controller
manual “Control parameter” section.
Sensor out of position.
Secure sensor properly.
System pressure too high.
Filling pressure too high.
Adjust system pressure to 50 psi (3.5 bar).
Expansion tank initial pressure too
high.
Isolate and adjust expansion tank to 40 psi
(2.8 bar).
Expansion tank too small.
Properly size and replace expansion tank.
System pressure too low.
Propylene glycol leak in system.
Check system for leaks and repair.
Expansion tank too small (release of
propylene glycol from relief valve).
Properly size and replace expansion tank.
Controller improperly set or sensor
defective.
Check program - Refer to controller manual
“Control parameter” section.
Temperature differential between
collector and storage tank too high.
Controller improperly set.
Check program - Refer to controller manual
“Control parameter” section.
Sensor out of position.
Secure sensor properly.
No power to pump.
Check controller and pump wiring.
Air or impurities present in system.
Properly commission system, purge all air.
Pump defective.
Replace pump.
Pump operates at night.
Normal on very warm nights.
None.
Check valve open or dirty.
Check position of check valves, clean or
replace if necessary.
Controller defective.
Replace controller.
Storage tank cools down rapidly.
Consumption higher than design for
system.
Reduce rate of hot water use.
Check valve open or dirty.
Check position of check valves, clean or
replace if necessary.
Insulation defective or inadequate.
Add, repair, or replace pipe insulation as
needed.