Page 25
3.
The heating fluid, which is heated in the heat source, is circulated between the heat source and tank’s coil.
The warmed fluid takes its heat from the heat source and transmits to the water heater.
4.
Free Hot Water tank inner surface is enameled. The meaning of enameled coating is as covering sheet
iron’s inside surface with glass.
5.
Free Hot Water tanks are protected by a magnesium anode rod in order to prevent the damage of cathode
corrosion. The magnesium anode rod ought to be replaced every 36 months by a certified plumber, and
can be installed and uninstalled. The replacement steps of the magnesium anode rod must be followed
according this manual.
6.
Free Hot Water exterior surface is covered by 2.5 lbs/cm³ (40 kg/m³) and 2” (50 mm) polyurethane (except
800D and 1000D) in order to diminish the loss of the heat. The Free Hot Water 800D and 1000D
1.
insulation foam is removable. This convenience allows easy delivery and access through narrow doors for
tank placement.
7.
The type of water heater to choose (single or double coil) depends on the heater and if you are planning to
extract heat. For example, if the tank will be heated with a solar system, Free Hot Water single coil water
heater would be appropriate.
8.
Free Hot Water SST have been produced to suit a wide range of applications and installation shapes.
2.
In this manual we present the most common applications, however if you require advice on any other
application, please contact our service desk on 408-432-9900 or [email protected]
Plumbing Connection
Delivering and mounting the Free Hot Water tank
1.
The product should be kept away from sharp tools during loading or delivering.
2.
The product’s inlet and outlet pipes should be protected against any damages during delivery.
3.
The product should not be left or placed where it’s exposed directly to weather such as direct sunlight, rain
snow etc.
4.
If possible leave headroom of one water heater length so the anode can be inspected or replaced.
Remember you may have to remove the entire water heater later for servicing as per instructions in this
manual.
5.
Outdoor installations decrease the water heater performance and may increase the energy consumption.
6.
If the product is installed on the floor, the floor must be dry and moisture proof.
7.
Consider a drainage tray when required.
8.
Tank must be strapped and mounted in accordance to local plumbing regulations and seismic regulations.
9.
Free Hot Water Limited does not accept any responsibility, if the product is physically damaged or operates
inefficiently due to wrong mounting or inappropriate delivery.
Basic Plumbing connection of the Water heater
1.
In order to use the water heaters to their highest efficiency, tanks must be connected according to the
diagrams.
2.
The capacity of the water resource has to be chosen and adjusted in order to maintain the hot water supply
demand.
3.
Start with the Basic Diagram before conducting any specific application connection.
4.
Fit the cold inlet valves prior to commissioning the tank.
5.
Ensure that the TPR Valve is fitted and that the service circulation is blocked or connected prior to
commissioning the tank with water.
6.
Lag all hot water pipes coming out of the water heater.