background image

®

TECHNICAL SPECIFICATIONS
Jack connector
The external equipment is powered by 5 V (max. 1 
A), delivered to the Tip of the plug. See figure.

The Ring of the plug is the signal fed into  
the counter. 

Triggering occurs on the falling  
slope at c. 2 V.

The Sleeve is ground

The DIN connector
1. Ground
2. +8V
3. Photo
4. 6.3 V AC
5. 6.3 V AC
6. Microphone

The two supply voltages have a max. load of 1 A.

The  Microphone  input triggers on the falling slope 
at c. 0.5 V. Sensitivity can be raised about 10 dB by 
shorting the Photo input to ground.

Apart from this, the Photo input is strongly specia- 
lized for use with Frederiksen’s photocell units.

Switch input
Triggering occurs on the 
rising slope – i.e. when the 
switch breaks – at c. 1.2 V.

When the switch is open, 
the input is pulled up to 

 

c.  7.4  V  which  must  be  ta-
ken into account if an elec-
tronic switch is used instead 
of a mechanical one. The 

 

generator impedance is c. 7.6 k

Ω

.

Pulse input
Triggering occurs on a falling slope at c. 70 mV (input 
A) resp. 1.7 V (input B). The maximum peak voltage 
tolerated is 50 V resp. 100 V for inputs A and B.

Mains power
The counter is powered by 230 V AC

The unit must be grounded and is provided with a 
grounded power cord.