![FRC TACH P3 TPA600 Manual Download Page 3](http://html1.mh-extra.com/html/frc/tach-p3-tpa600/tach-p3-tpa600_manual_2329198003.webp)
TPA600 Rev170623
3
INTRODUCTION
Overview
The Engine Monitoring Display is an all-in-one instrument panel with integrated
monitoring and display capabilities that saves valuable pump panel space. It combines
four different instruments in one waterproof unit. It provides both audible and visual
warning alarms if specified parameters go outside of set limits.
The Engine Monitoring Display has a 4-digit LED display for engine RPM and
3-digit LED displays for engine oil pressure, engine coolant temperature, and battery
voltage. During normal operation warning messages are displayed as they occur.
The Engine Monitoring Display receives input information form the J1939 CAN
bus.
Features
Non-Multiplexed Display Means No Flickering
Digital Engine RPM, Oil Pressure, and Coolant Temperature Displays
Battery Voltage Display with Low and Over Voltage Warnings
Automatically Adjusts to 12 or 24 Volt System
Programmable Parameters
Audible and Visual Warnings
LED Brightness Automatically Adjusts for Day or Night Operation
Transmission Temperature Displayed (When Available)
Specifications
Display Module
Supply Power:
12/24 VDC/ Auto Detected
Supply Current:
1.5 Amps
Dimensions:
4.2" by 4.2" by 0.7"
Audible Alarm Buzzer
Volume:
95
dB