![FRC TACH P3 TPA600 Manual Download Page 11](http://html1.mh-extra.com/html/frc/tach-p3-tpa600/tach-p3-tpa600_manual_2329198011.webp)
TPA600 Rev170623
11
Table 2. Program Functions
CODE DESCRIPTION
OPTIONS and NOTES
FACTORY DEFAULT
P01
Units of measure
Select
PSI, kPa, Bar
°F, °C
PSI and °F
P02
Low oil pressure
warning
Set Value
(Set to 0 to synchronize
warning with dash light.)
8 PSI
P03
High engine temperature
warning
Set Value
(Visual warning occurs 10 °F
below audible setting.)
(Set to 0 to synchronize
warning with dash light.)
230 °F
P04
1
Low battery voltage
warning - engine running
Set Value
11.8/ 23.6 VDC
P05
1
High battery voltage
warning - engine running
Set Value
15.4/31.0 VDC
P06
1
Low battery voltage
warning - engine off
Set Value
11.7/23.4 VDC
P07
Transmission
temperature enable/
disable
Select
yes - enabled
(
MENU
button is pressed to
show temp.)
no - disabled
yes
P08
High transmission
temperature warning
Set Value
300 °F
P09
2
Battery voltage source Select
bus - voltage is read from
J1939 CAN bus
loc - voltage is read from the
module input pins
bus
Notes:
1 - Module automatically detects 12 or 24 volt input.
2 - When set to bus and no voltage information is available on J1939, the module automatically
reads the voltage from the module input pins.
CODE DESCRIPTION
P20
Model number
P21
Software revision
P22
Serial number
P23
Manufacturing date
P24
Hardware revision
P25
J1939 CAN Bus terminator
The following are read only functions.