![FRC INSIGHT iPF-10 Manual Download Page 21](http://html1.mh-extra.com/html/frc/insight-ipf-10/insight-ipf-10_manual_2329244021.webp)
IPF Rev0204
21
Error Code E202
An invalid program code has been entered. Re-enter program code when the digital
display resets.
Error Code E204
There is no signal from the sensor. This code will only be displayed when in a
calibration mode. Troubleshoot the sensor and the associated wiring.
Error Code E206
A selected calibration point is to close to the previous point. (There is less than
5% difference between two calibration points.) Select a different point to continue
with the calibration procedure.
Error Code E208
There is a failure with the internal memory of the module. Contact FRC if this
error code is displayed.
Exit Program Access Mode
Press both the
MODE
and
TOTAL
buttons and hold them there until four dashes
are shown in the display. Release the buttons and after 3 seconds the program will
return to normal operation.