ICA900 Rev150324
4
INSTALLATION
Install Control Module
The control module is mounted with a bracket or to the surface with a panel cutout
for the connector.
Bracket Mount
Note:
The mounting bracket can be removed by unscrewing the adjustment
knobs at the side of the control module.
1. Measure and mark mounting location for control module bracket. Refer to
Figure 1 for layout and dimensions.
2. Drill two mounting holes (clearance or tapped) for mounting 10-32 hardware.
3. Place mounting bracket in position and secure with two screws.
4. If bracket was removed from module, place module in position and install
rubber bushings and mounting knobs.
5. Connect the cables and wiring. Provide enough slack in the cable(s) for the
control module to be adjusted as needed. (Refer to Wiring Section).
Surface Mount
1. Measure and mark mounting location for control module panel cutout and
mounting screw holes. Make sure there is clearance behind the panel for the
connector and wiring before cutting holes. Refer to Figure 1 for layout and
dimensions.
2. Cut out a 1 3/8" wide by 2 3/8" high hole for the connector to fit through and
drill two holes (clearance or tapped) for 10-32 mounting screws.
3. Place control module in position and secure with two screws.
4. Connect the cables and wires. (Refer to Wiring Section).