Page | 15
PLEASE DON’T USE THE GENERATOR WHILE THE RV IS IN MOTION!
The generator is controlled via the integrated touch pad which is located on the wall left of the bathroom door.
Turning the Generator ON
1.
Turn off all electrical devices
2.
Press and hold
①
to start the generator. Please note that the generator requires a press and hold because it
operates on a one-second delay as a safety feature to help prevent accidental generator starts.
3.
When the microwave beeps (30 – 40 seconds) the power circuit is closed and you can use the electrical
devices.
Turning the Generator OFF
1.
Turn off all electronic devices.
2.
Press and hold
②
to stop the generator.
Troubleshooting: Generator
Problem
Cause/Solution
Generator does not start
-
The fuel tank level is below ¼.
-
Start button pressed too short. It need to be pressed for approx. 10 seconds
(sometimes longer)
-
Weak coach battery. Start the engine and then the generator.
-
Blown or burnt fuse. Please check the fuses in the fuse box and on the
generator, and replace plug-in fuses if required
Fuse is tripped
The circuit is overloaded. If too many appliances are used simultaneously, the
fuse may be tripped while the generator is running. Please turn off the
appliances, check the 110V breaker in the fuse box, and restart the generator. If
all breakers in the fuse box are in the ON position, please check the breaker right
on the generator (see below picture).
SAFETY INSTRUCTIONS:
1.
Keep the compartment clean and dry at all times, and do not use this as a compartment for storage.
2.
Do not use the generator when the motorhome is parked in high grass or in scrubby terrain because the heat
of the exhaust fumes may cause a fire in dry conditions.
3.
Do not touch the generator while it is running or shortly after it has been turned off to avoid burns.
SOLAR SYSTEM
Your RV is equipped with a solar system on the roof, which recharges the coach battery
when exposed to sunlight. The solar system is automated and does not require manual
operation. Please do not make any changes to the default settings on the control panel.
START switch
Generator
breaker
Please remove the green generator
cover to check the breaker (small black
lever) on the side of the generator.
Apart from that, there is also a start
switch above it directly on the
generator.