2. SAFETY
Warnings:
-
The Anti-Static Bar is only designed for neutralising surfaces with an electrostatic charge.
-
Electrical installation must only be carried out by suitably qualified personnel.
-
Adequate installation earth / ground is required to ensure safe and proper operation.
-
The 0 V return of the 24 V DC electrical supply must be earthed.
-
Disconnect the power supply before cleaning or handling the Bar.
-
The emitters are sharp and can cause physical injury.
-
There are no user serviceable parts inside the Bar.
-
Ensure the Bar and connecting cable are free from damage prior to installation and check periodically once in use.
-
Bar must be switched off before removing or reconnecting the signal cable.
-
A small amount of ozone will be produced as part of the ionisation process. When installed correctly the level of concentration
of ozone is less than 0.1 ppm and is within internationally accepted limits.
Any changes to the equipment without written consent of the manufacturer will nullify the warranty and CE certification.
As with all pulsed DC static eliminators, it is possible for the user to receive a small static shock as a result of
their body being charged by the bar, and then discharging to a nearby earthed object. This is not dangerous,
but may be uncomfortable and cause surprise. It is for this reason that the signal cable must not be removed or
reconnected when the bar is powered.