![Fraser NEOS 30 OEM Manual Download Page 21](http://html1.mh-extra.com/html/fraser/neos-30-oem/neos-30-oem_manual_2329146021.webp)
Fraser Anti-Static Techniques, Scotts Business Park, Bampton, Devon EX16 9DN, UK
T + 44 (0) 1398 331114 F + 44 (0) 1398 331411 E [email protected] W www.fraser-antistatic.com
21
NEOS 30 OEM-DM-Iss.2
10. CERTIFICATION AND EU DECLARATION OF CONFORMITY
We declare that this equipment conforms to the Low Voltage Directive, and EMC Directive. It is entitled to display the CE and UL
marks.
For further instructions and information, please contact the manufacturer.
11. TROUBLESHOOTING
On power-up, the status LED will be RED for up to 3 seconds while internal checks are being carried out inside the bar. After this
time, if all operating conditions are normal, the status LED will turn GREEN.
If the status LED does not illuminate GREEN or RED, then check the electrical supply. If the electrical supply is OK, then check the
connecting cables for damage.
If the status LED is in SOLID RED, then this indicates overload or other fault:
- Turn the power off and clean the bar.
- Check the electrical supply.
- Check the installation location is as described in this manual.
LED / Signal
Problem
Cause
No LED
No 24 V power
No supply or voltage too low
Faulty wiring
Action
Check supply voltage
Check wiring
Solid Red
No high voltage at emitter
Power supply out of voltage range
Bar overloaded
High voltage supply fault
Check power supply voltage
Clean Bar
Flashing Red
& Green
Poor ionisation
Dirty Bar
Bar overloaded
Bar incorrectly positioned
Clean Bar
Check positioning of Bar
Check emitters for damage