PUMPTEC-PLUS Pump Protection System
9
Operation cont.
A. Green Light
The green light (A) indicates that the status of the pump system is normal.
A SOLID GREEN LIGHT indicates that Pumptec-Plus has power and the contactor to the motor
is closed but the motor is not running. This may happen when the pressure switch is wired in
down-line from Pumptec-Plus and the switch is open. Pumptec-Plus is waiting for the pressure
switch to close.
A FLASHING GREEN LIGHT indicates the pump motor is running normally and drawing the
correct amount of power.
B. Yellow Light
The yellow light (B) indicates that a load fault has occurred.
A SOLID YELLOW LIGHT indicates an underload fault occurred. The Pumptec-Plus automatic
restart timer will restart the motor in accordance with the position of the automatic restart timer
switch setting. The switch should be set at the time of installation (refer to step 2). If set in the
manual position, Pumptec-Plus must be reset manually by pushing the RESET BUTTON (D).
A FLASHING YELLOW LIGHT indicates an overload condition occurred. This means that the pump
system power draw was greater than the normal operating power (calibration) by more than 25%
for more than 2.5 seconds. Pumptec-Plus will not run the pump system again until the RESET
BUTTON (D) is pressed.
A. GREEN LIGHT
B. YELLOW LIGHT
C. RED LIGHT
D. RESET BUTTON
Summary of Contents for PUMPTEC-PLUS
Page 1: ...PUMPTEC PLUS Pump Protection System Installation and Operating Guide ...
Page 14: ...NOTES ...
Page 15: ...NOTES ...
Page 17: ...PUMPTEC PLUS Sistema de protección de bombas Guía de instalación y funcionamiento ...
Page 30: ...NOTAS ...
Page 31: ...NOTAS ...
Page 33: ...PUMPTEC PLUS Système de protection de pompe Instructions d installation et de fonctionnement ...
Page 46: ...REMARQUES ...
Page 47: ...REMARQUES ...