13
The installer settings provide access to the water softener cycle times. The factory settings have been
programmed for maximum efficiency. Altering the factory programmed cycles will affect the softeners
performance. NOTE: Extreme caution must be taken when adjusting the water softener cycles. Decreasing a
cycle time or completely deleting the cycle may cause the softener to stop functioning.
“Home” screen displays current time-of-day.
Press and HOLD ‘CHECKLIST’ button for approximately 3 seconds to access installer settings.
Ensure the
Iron
indicator is illuminated on the left side of the
display and using the ‘
↑’
and ‘
↓’
buttons set the incoming iron
concentration.
NOTE: While a water softener can be reasonably
expected to remove small amounts of clear water iron,
for best performance an iron filter should be
considered.
Press ‘NEXT’ button to set incoming HARDNESS level.
Ensure the
Hardness
indicator is illuminated on the left side of
the display and using the ‘
↑’
and ‘
↓’
buttons set the incoming
hardness level.
NOTE: This softener is set to calculate hardness as
grains per gallon (gpg). If your water hardness is
reported in milligrams per liter (mg/l) or parts per
million (ppm) divide these results by 17.1 to convert to
grains per gallon.
Press ‘NEXT’ button to set regeneration DAYS
OVERRIDE interval
Using ‘
↑’
and ‘
↓’
, set the desired day override interval. The
regeneration day override function will cause the softener to
regenerate after a designated period of no regeneration cycles. The
override interval will reset after every regeneration cycle whether
initiated manually or by volume. The day override function will be
disabled if the VACATION mode is active.
Press ‘NEXT’ button to set REGENERATION TIME hours.
Display and Operation
– Installer Settings – Cycles
Ensure the
Regen Time
indicator is illuminated. Using ‘
↑’
and ‘
↓’
,
set the desired time of regeneration hours. Note the AM
and PM
indicator and set the time accordingly.
Press ‘NEXT’ button to set REGENERATION TIME minutes.