SubDrive Connect
25
SubDrive2200
The SubDrive2200 is capable of use with 1.1 kW (1.5 hp) pumps that are mounted to 2.2
kW (3.0 hp) Franklin Electric three-phase motors. In general, the SubDrive2200 will enhance
the performance of a 1.1 kW (1.5 hp) pump to a similar or better performance than a
conventional 2.2 kW (3.0 hp) pump of the same ow rating (pump series).
To select the proper
1.1 kW (1.5 hp) pump,
rst choose a 2.2 kW
(3.0 hp) curve that meets
the application’s head
and ow requirements.
Use the 1.1 kW (1.5 hp)
pump in the same pump
series ( ow rating). The
SubDrive2200 will adjust
the speed of this pump to
produce the performance
of the 2.2 kW (3.0 hp)
curve. An EXAMPLE of this
is illustrated in the graph
at right. Please consult
the pump manufacturer’s
pump curve for your
speci c application.
The SubDrive2200 can also be set up to run a 1.5 kW (2.0 hp) or 2.2 kW (3.0 hp) pump if
desired, but larger pumps will still produce to the 2.2 kW (3.0 hp) curve and may only be
operated with a 2.2 kW (3.0 hp) motor. To operate a di erent pump size, a DIP switch must
be positioned to select the correct pump rating. Otherwise, the SubDrive2200 may trigger
erroneous faults.
See the Basic Setup section of this manual for DIP switch information and settings.
Serious or fatal electrical shock may result from contact with internal electrical components.
DO NOT, under any circumstances, attempt to modify DIP switch settings until power has been
removed and 5 minutes have passed for internal voltages to discharge! Power must be removed for
DIP switch setting to take e ect.
EXAMPLE 3
Typical SubDrive2200 Performance
1.1 kW (1.5 hp), 25 GPM with SubDrive2200
Conventional 2.2 kW (3.0 hp) 25 gpm Pump
Conventional 1.1 kW (1.5 hp) 25 gpm Pump
WARNING
V
!
EN