SubDrive/MonoDrive
37
Specifications – MonoDrive/MonoDriveXT
MonoDrive
MonoDriveXT
Model No.
NEMA 1 (indoor)
587 020 3110
587 020 4110
NEMA 3R
(indoor/outdoor)
Not Available
Not Available
NEMA 4 (outdoor)
587 020 3114
587 020 4114
Input from
Power Source
Voltage
190-260 VAC
190-260 VAC
Phase In
Single-Phase
Single-Phase
Frequency
60/50 Hz
60/50 Hz
Current (max)
5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW system
13 Amps (RMS) 1.5 hp, 1.1 kW system
16 Amps (RMS) 2 hp, 1.5 kW system
Power Factor
1.0 (constant)
1.0 (constant)
Power (idle)
35 Watts
65 Watts
Power (max)
1150 Watts (1/2 hp, 0.37 kW) system
1750 Watts (3/4 hp, 0.55 kW) system
2150 Watts (1 hp, 0.75 kW) system
2500 Watts (1.5 hp, 1.1 kW) system
3100 Watts (2 hp, 1.5 kW) system
Wire Gauge Size(s)
Consult Federal, State, and Local codes
for branch circuits installations
Consult Federal, State, and Local codes for branch
circuits installations
Output to
Motor
Voltage
Adjusts with Frequency
Adjusts with Frequency
Phase Out
Single-Phase (3-wire)
Single-Phase (3-wire)
Frequency Range
30-60 Hz
30-60 Hz
Current (max)
Main Phase: 6 Amps (RMS)
1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS)
3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS)
1 hp, 0.75 kW system
Main Phase: 11.5 Amps (RMS)
1.5 hp, 1.1 kW system
Main Phase: 13.2 Amps (RMS)
2 hp, 1.5 kW system
Wire Gauge Size(s)
NEMA 1 #10 - #16 * ga.
NEMA 4 #6 - #18 * ga.
NEMA 1 #6 - #18 * ga.
NEMA 4 #6 - #18 * ga.
Pressure
Setting
Factory Preset
50 psi (3.4 bar)
50 psi (3.4 bar)
Adjustment Range
25-80 psi (1.7 - 5.5 bar)
25-80 psi (1.7 - 5.5 bar)
Operating
Conditions
(A)
Temperature
(at 230 VAC input)
-13 °F to 125 °F (-25 °C to 50 °C)
-13 °F to 125 °F (-25 °C to 50 °C)
Relative Humidity
(NEMA 1)
10-95%, non-condensing
10-95%, non-condensing
Relative Humidity
(NEMA 3R)
Not Available
Not Available
Relative Humidity
(NEMA 4)
0-100%, condensing
0-100%, condensing
Controller
Size
(B)
(approximate)
NEMA 1 (indoor)
16 1/2" x 12 3/8" x 9"
(41.91 x 31.43 x 22.86 cm)
15.00 lbs (6.80 kg)
16 1/2" x 12 3/8" x 9"
(41.91 x 31.43 x 22.86 cm)
17.50 lbs (7.94 kg)
NEMA 3R
Not Available
Not Available
NEMA 4 (outdoor)
17 1/2" x 16 3/8" x 11 3/8"
(44.45 x 41.59 x 28.89 cm)
24.14 lbs (10.95 kg)
17 1/2" x 16 3/8" x 11 3/8"
(44.45 x 41.59 x 28.89 cm)
28.32 lbs (12.84 kg)
For Use With
(C)
Pump (60 Hz)
1/2 hp pump/motor with 214505 - series
3/4 hp pump/motor with 214507 - series [default]
1 hp pump/motor with 214508 - series
1.5 hp pump/motor with 224300 - series [default]
2 hp pump/motor with 224301 - series
FE Motor Rating
Notes:
(A) Operating temperature is specified at full output power when installed as described in Controller Location Selection on pg. 22.
(B) Refer to pg. 41 for detailed Mounting Dimensions.
(C) If a pump other than the default rating is used, refer to pgs. 14-15 for Drive Configuration.
* Refer to pg. 28 for detailed Circuit Breaker and Wire Sizing.
Summary of Contents for MonoDrive
Page 45: ...SubDrive MonoDrive 45 Notes ...
Page 46: ...46 SubDrive MonoDrive Notes ...