Inline Constant Pressure System
7
Incoming Pressure Requirement
The Inline System is designed to operate as low as 3 psi (0.2 bar) at minimum incoming pressures.
When used on a cistern, the incoming pressure requirement is waived, but a water level must be
maintained in the cistern to prevent a vortex from forming.
Failure to maintain incoming water may result in heating of water,
personal injury, pump damage and/or property damage.
Suction Piping
When the pump is located at a distance from the water source, the suction piping may have to be
increased in diameter to reduce friction loss. The friction loss in a system increases:
1.
As the flow rate increases
2.
As the piping size decreases
Refer to the included Inline System’s performance tables (Appendix 1) and friction loss tables
(Appendix 2) to determine the amount of head lost for a given application.
Discharge Pipe Sizes for Installation
When the pump is located at a distance from points of water use, it is necessary to increase the
discharge pipe size in order to reduce friction loss. The friction loss in a system increases:
1. As the flow rate increases
2. As the piping size decreases
Refer to the included Inline System’s performance tables (Appendix 1) and friction loss tables
(Appendix 2) to determine the amount of head lost for a given application.
Pressure Tank
The Inline System needs a small pressure tank placed on the pump outlet to maintain constant
pressure. The tank supplies water while the pump ramps up to speed and in circumstances where
only a small amount of water is required for a short period of time. In addition, the tank prevents
water hammer by acting as a system buffer. This buffer also helps to prevent pressure spikes
when there is a sudden change in demand.
s
WARNING
!
WARNING
System Pressure
(at Pressure Sensor)
Pressure Tank
Setting (±2 PSI)
25
18
30
21
35
25
40
28
45
32
50 Factory Setting
35
55
39
60
42
65
46
70
49
75
53
80
56
NOTE:
1 psi = 0.068 bar
Summary of Contents for Inline 1100
Page 1: ...Inline Constant Pressure System Owner s Manual...
Page 21: ...NOTES...
Page 22: ...NOTES...
Page 25: ...Sistema de Presi n Constante Inline Manual del Proprietario...
Page 45: ...NOTAS...
Page 46: ...NOTAS...
Page 49: ...Manual du propri taire Syst me de Pression Constante Inline...
Page 69: ...REMARQUES...
Page 70: ...REMARQUES...