background image

10

force. 

Supply  voltage,  current  and  cos  φ  are  quoted  on  the 

motor plate that has to be kept within the electrical panel.

 

m

The  motor  must  be  earthed  and  connected  to 

the electric panel.

 

4.2  Verification of Rotation Direction

When the pump has been connected to the power supply, 

establish the current direction of rotation as follows:

1.  Start  the  pump  and  control  the  head  provided  with 

gate valve not fully closed.

2.  Stop  the  pump  and  interchange  two  of  the  phase 

connections.

3.  Start the pump and repeat step 1.  with the gate valve 

in the same position.

4.  Stop the pump.

Compare  the  results  obtained  after  performing  steps  1 

and 3. The correct connection is the one that gives the 

highest head.

Note:

  The  pump  must  not  be  started  until  the  suction 

support has been completely submerged.

5 .  PUMP INSTALLATION

 

m

Before starting any work on the pump or on the 

motor,  make  sure  that  the  power  supply  has 

been disabled and that it cannot be accidentally 

switched on.

5 .1  Assembling of the pump with the motor

Place  the  pump  on  the  motor  in  order  that  they  are 

positioned along the same axis and insert the motor shaft 

in the pump shaft joint: the coupling must not be forced.

Tighten  the  screws  or  the  nuts  that  diagonally  fix  the 

pump-motor  flanges  with  a  driving  torque  as  quoted  in 

the following table.

Motor type

Screw

Driving torque 

Nm

Motor 4"

M8

18

Motor 6"

M12

100

Motor 8"

M16

200

5 .2  Delivery piping

If the pump is already coupled to the delivery piping and 

you use a chain pipe wrench, tighten the pump, holding it 

only by the delivery opening.

The threaded pipes must be connected in such a way as 

to support the unscrewing action due to the starting and 

stopping of the pump.

The thread of the pipe, which has to be screwed into the 

pump, should not be longer than the thread of the pump.

After screwing the pipe into the delivery opening, tighten 

the screw assembled to avoid the loosening of the first 

section of the pipe, see Fig. 3.

When  plastic  pipes  are  used,  the  pump  should  be 

secured  by  an  unloaded  rope  to  be  fastened  to  the 

delivery opening, see Fig. 3.

001

14016   09/2008

001

14016   06/2010

Fig. 3

5.3  Cable fitting 

Use  cable  clips  every  3  meters  to  fix  the  cable  to  the 

support rope or to the delivery pipe.

Use plastic cable clips as shown in Fig. 4. 

Once the cable has been fastened, cut off the remaining 

part of the clip.

3mt

3mt

001

14019   09/2008

001

14019   06/2010

Fig. 4

In  the  case  that  the  tube  is  plastic,  it  must  leave  the 

electric  cable  and  the  cable  support  not  in  tension  to 

prevent the elongation of the tube, due to the weight of 

the water contained in it, tearing the electric cable. 

Summary of Contents for E-Tech Series

Page 1: ... DRÄNKBARA PUMPAR 4 6 И 8 ПОГРУЖНЫЕ НАСОСЫ Manuale d uso e installazione Use and installation instructions Gebrauchs und Aufstellungshandbuch Manuel pour l emploi et installation Manual de empleo e instalación Instrukcja obsługi i instalacji Brugs og installationsanvisninger Käyttö ja asennus ohjeet Οδηγίες χρήσης και εγκατάστασης Gebruiks en installatie instructies Instruks for bruk og installasj...

Page 2: ... physical and material damages as well as environmental pollution Non compliance with safety instructions will also lead to the complete loss of any warranty right In particular the inobservance of the above mentioned instructions may for example result in failure of main machine unit functions failure of maintenance procedures hazard of electrical mechanical or chemical nature Safety regulations ...

Page 3: ...coupling must be avoided The pump might for instance be equipped with a protective shield The pump is suitable for both vertical and horizontal installation however the pump should never be installed inclined downwards see Fig 2 Note During operation the suction support must always be completely submerged In special conditions it may be necessary to submerge the pump even deeper depending on the o...

Page 4: ...ts that diagonally fix the pump motor flanges with a driving torque as quoted in the following table Motor type Screw Driving torque Nm Motor 4 M8 18 Motor 6 M12 100 Motor 8 M16 200 5 2 Delivery piping If the pump is already coupled to the delivery piping and you use a chain pipe wrench tighten the pump holding it only by the delivery opening The threaded pipes must be connected in such a way as t...

Page 5: ... valve closed to 1 3 Check the direction of rotation as described in section 4 2 Verification of Rotation Direction If there are impurities in the water the gate valve should be opened gradually until the water becomes clearer The pump should not be stopped until the water is completely clean again since otherwise the pump parts and the non return valve may be damaged If the pump flow rate is high...

Page 6: ...Pull out the assembly and clean it Delivery valve closed or blocked Find and replace the defective valve Pump silted up Pull out the assembly and clean it Wrong direction of rotation Carry out instructions as in 4 2 Pump capacity exceeds well capacity Replace pump with one of lower capacity Leaks in the system Locate leaks and repair them Worn pump Pull out the assembly and overhaul it Pressure sw...