12
9 . TROUBLESHOOTING
●
Zero flow rate
●
Poor flow rate
●
Poor pressure
●
The pump starts and stops too frequently
●
Excessive current absorbed by the electro-pump
Possible causes related to the pump
(Motor and panel excluded)
Solution
██ █
Well water level too low
Wait until well water level is restored, or if
possible, lower the pump further
██
Suction screen clogged
Pull out the assembly and clean it
██
Delivery valve closed or blocked
Find and replace the defective valve
█
█
Pump silted up
Pull out the assembly and clean it
██ █
Wrong direction of rotation
Carry out instructions as in 4.2
█ █
Pump capacity exceeds well capacity
Replace pump with one of lower capacity
█
Leaks in the system
Locate leaks and repair them
█
Worn pump
Pull out the assembly and overhaul it
█
Pressure switch or level control improperly set
Adjust setting
█
Tank too small
Replace tank with a larger one
█
Mechanical friction
Pull out the pump and overhaul it