background image

12

9 .  TROUBLESHOOTING

Zero flow rate

Poor flow rate

Poor pressure

The pump starts and stops too frequently

Excessive current absorbed by the electro-pump

Possible causes related to the pump

(Motor and panel excluded)

Solution

██ █

Well water level too low

Wait  until  well  water  level  is  restored,  or  if 

possible, lower the pump further

██

Suction screen clogged

Pull out the assembly and clean it

██

Delivery valve closed or blocked

Find and replace the defective valve

Pump silted up

Pull out the assembly and clean it

██ █

Wrong direction of rotation

Carry out instructions as in 4.2

█ █

Pump capacity exceeds well capacity

Replace pump with one of lower capacity

Leaks in the system

Locate leaks and repair them

Worn pump

Pull out the assembly and overhaul it

Pressure switch or level control improperly set

Adjust setting

Tank too small

Replace tank with a larger one

Mechanical friction

Pull out the pump and overhaul it

Summary of Contents for E-Tech Series

Page 1: ... DRÄNKBARA PUMPAR 4 6 И 8 ПОГРУЖНЫЕ НАСОСЫ Manuale d uso e installazione Use and installation instructions Gebrauchs und Aufstellungshandbuch Manuel pour l emploi et installation Manual de empleo e instalación Instrukcja obsługi i instalacji Brugs og installationsanvisninger Käyttö ja asennus ohjeet Οδηγίες χρήσης και εγκατάστασης Gebruiks en installatie instructies Instruks for bruk og installasj...

Page 2: ... physical and material damages as well as environmental pollution Non compliance with safety instructions will also lead to the complete loss of any warranty right In particular the inobservance of the above mentioned instructions may for example result in failure of main machine unit functions failure of maintenance procedures hazard of electrical mechanical or chemical nature Safety regulations ...

Page 3: ...coupling must be avoided The pump might for instance be equipped with a protective shield The pump is suitable for both vertical and horizontal installation however the pump should never be installed inclined downwards see Fig 2 Note During operation the suction support must always be completely submerged In special conditions it may be necessary to submerge the pump even deeper depending on the o...

Page 4: ...ts that diagonally fix the pump motor flanges with a driving torque as quoted in the following table Motor type Screw Driving torque Nm Motor 4 M8 18 Motor 6 M12 100 Motor 8 M16 200 5 2 Delivery piping If the pump is already coupled to the delivery piping and you use a chain pipe wrench tighten the pump holding it only by the delivery opening The threaded pipes must be connected in such a way as t...

Page 5: ... valve closed to 1 3 Check the direction of rotation as described in section 4 2 Verification of Rotation Direction If there are impurities in the water the gate valve should be opened gradually until the water becomes clearer The pump should not be stopped until the water is completely clean again since otherwise the pump parts and the non return valve may be damaged If the pump flow rate is high...

Page 6: ...Pull out the assembly and clean it Delivery valve closed or blocked Find and replace the defective valve Pump silted up Pull out the assembly and clean it Wrong direction of rotation Carry out instructions as in 4 2 Pump capacity exceeds well capacity Replace pump with one of lower capacity Leaks in the system Locate leaks and repair them Worn pump Pull out the assembly and overhaul it Pressure sw...

Reviews: