INSPECT THE SHIPMENT

                       Before installing jet charger on tank, 
make sure that tank tapping (or hex bushing) is free of 
excess galvanize flashings or any other obstruction. 
Clean tapping by screwing a steel pipe plug into the 
tapped opening and removing it. Otherwise an obstructed 
tapping will damage the jet charger threads.
For best operation, the jet charger should be installed in 
a tapped opening located approximately 1/2 the height of 
the tank. Where the tank is in a horizontal position, the jet 
charger is connected in the center opening at one end of 
the tank.
Figure 1 & 2 - Assemble plastic tubing and fittings as 
shown. With the jet charger body in a vertical position, 
attach one end of the plastic tubing to the bottom opening 
of the jet charger, and the other end to the suction of the 
pump. (See Fig. 2)

CAUTION

CAUTION

OWNER'S MANUAL

MODEL 225A AUTOMATIC 

JET CHARGER

                         Pipe compounds are not necessary to 
seal and may damage plastic. Also avoid over-tightening.
Figure 3  - Use 7/8” wrench on plastic elbow, as shown. 
Do not tighten by applying pressure to plastic body as 
illustrated.
NOTE: The joint between the plastic elbow and the jet 
charger body contains a rubber O-ring for sealing. This 
joint should only be hand tightened.

OPERATION

The jet charger is especially designed to maintain the 
proper ratio of air and water in the pressure tank. When 
the water level in the tank is above the jet charger inlet, 
the charger will function in conjunction with the pump 

Adapter Nut

Air Charger

Poly. Tubing

Male Connector

FIGURE 1

FIGURE 2

FIGURE 3

CORRECT

WRONG