background image

No.

Description

1

Pre-installed condensate pump unit

2

Pressure lines plastic bag includes:
transparent hose for pressure line, approx. 15 cm long
transparent hose for pressure line, approx. 150 cm long
3 x cable ties, approx. 30 cm long
self-adhesive hook-and-loop fastener strip (not required for profi-air 180 flat)

3

Anti-lift valve

4

Transparent silicone hose for pressure compensation, approx. 200 cm long

5

Connection cable to connect condensate pump to profi-air 180 flat control board

6

Cable and installation accessories plastic bag includes: 
2 x screws to secure the condensate pump unit to profi-air 180 flat 
Y-cable to connect condensate pump to profi-air 180 flat control board
2-pin connector plug for power supply of the condensate pump
2-pin connector plug to connect condensate pump to digital input on the control board 

profi-air 180 flat (high water level alarm signal)

7

Inlet hose, Ø 12 mm x 210 mm  

(only required if the profi-air 180 flat ventilation unit has been installed vertically on the wall)

8

Connection nipple for inlet hose  

(only required if the profi-air 180 flat ventilation unit has been installed vertically on the wall)

9

Alternative condensate housing (not required for profi-air 180 flat)

1

4

7

2

5

8

5.1 Parts overview of the entire condensate pump kit

5  Installation

3

6

9

Installation / operating instructions – profi-air 180 flat condensate pump

7

Summary of Contents for profi-air 180

Page 1: ...profi air 180 flat condensate pump Installation operating instructions Building Technology www fraenkische com...

Page 2: ...Installation operating instructions profi air 180 flat condensate pump 2...

Page 3: ...rs cannot be entirely excluded We also reserve the right to make changes to our products specifications and other data Changes may also become necessary as a result of legal material related or other...

Page 4: ...nce for service and maintenance work and thus guarantee smooth and efficient operation 1 2 Safety If used for the intended purpose the device is safe and reliable to operate The construction and desig...

Page 5: ...ectly connected to the control of the profi air 180 flat ventilation unit Depending on the operating mode of the ventilation unit A or B it must always be installed on the exhaust air fresh air side T...

Page 6: ...ousing can operate properly Q Horizontal ventilation unit installation ceiling installation mount condensate pump on the housing wall of the ventilation unit Q Vertical ventilation unit installation w...

Page 7: ...nit to profi air 180 flat Y cable to connect condensate pump to profi air 180 flat control board 2 pin connector plug for power supply of the condensate pump 2 pin connector plug to connect condensate...

Page 8: ...i b rat i o n Cal i b raz i o ne 0 120 100 80 60 40 20 110 90 70 50 30 10 0 60 40 100 160 140 200 20 80 120 180 m 3 h Pa Air flo w A B U S B max 45 C ALin ksv ers i o n A Lef t uni t uni t sin i s tr...

Page 9: ...ali brat i o n Cali braz i o ne 0 120 100 80 60 40 20 110 90 70 50 30 10 0 60 40 100 160 140 200 20 80 120 180 m 3 h Pa Air flow A B US B Digital input J1 J19 RS485 J22 1 2 1 2 1 2 1 2 1 4 2 5 1 3 2 4...

Page 10: ...1 P2 P4 P1 P2 Pa P3 P4 m 3 Pa m 3 Eins tellw erte Cali brat i o n Cali braz i o ne 0 120 100 80 60 40 20 110 90 70 50 30 10 0 60 40 100 160 140 200 20 80 120 180 m 3 h Pa Air flow A B US B ALinks vers...

Page 11: ...as been developed and produced for use in so called comfort ventilation systems Any other use is considered improper and can lead to damage to the profi air flat ventilation unit or personal injury wh...

Page 12: ...o change without notice Cat No 5000 1343 00 01 2018 FR NKISCHE Rohrwerke Gebr Kirchner GmbH Co KG Hellinger Str 1 97486 K nigsberg Germany Phone 49 9525 88 2200 Fax 49 9525 88 92200 marketing fraenkis...

Reviews: