![FRÄNKISCHE 100 DATALIGHT Operating Instructions Manual Download Page 12](http://html1.mh-extra.com/html/frankische/100-datalight/100-datalight_operating-instructions-manual_2328189012.webp)
12
FRÄNKISCHE |
OI WLAN Access Point 100 DATALIGHT
®
The following settings are possible:
n
Enable/disable WLAN
(WLAN de-/aktivieren)
The WLAN interface can be disabled
when not in use to avoid radiation
and to save energy. The other two
interfaces are still available. Switch-
ing can also be implemented via UDP
(see page 18).
n
Channel
(Kanal)
The frequency ranges of nearby
channels overlap. You should there-
fore select the channel such that the
frequencies of other wireless devices
nearby do not overlap (e.g., radio
microwave devices in the range of
channels 9, 10). In Germany, 13 chan-
nels are allowed, e.g., in the USA only
11. We thus recommend using the
channels 1 to 11 only.
n
Transmission performance
(Sendeleistung)
By changing the transmission perfor-
mance, you can adjust the range of
the WLAN AP to local conditions. It
should be kept rather small in accord-
ance with the area of application.
The settings possible in interface configuration are network-specific:
n
ESSID
Network name with which the WLAN
AP shall be connected.
n
Mode (Modus)
Four modes are available:
the operating modes Access Point,
Access Point (WDS/Repeater), Client
(WDS) and Client (RELAYED) – see
pages 5-7.
n
Hide ESSID (ESSID verstecken)
prevents unauthorized
devices from seeing your network.
Device configuration – general settings
Interface configuration – general settings
3 Configuration
Click “Save & Apply” (Speichern & Anwenden) to apply the entries.