background image

3 | Usage

Franke Kaffeemaschinen AG

20

User manual SU12/UT12

Cleaning of cooling unit

Regular cleaning is a prerequisite for the unspoiled, safe enjoyment of drinks.
You can find more detailed information on operating, configuring, cleaning
and caring for your cooling unit in the user manual for your coffee machine. In
addition, the separate cleaning instructions describe the cleaning of the re-
movable components.
Clean the milk/drinks system daily or when prompted by the coffee machine.
Clean the cooling unit and components with warm water and a mild cleaner.
Use a dry cloth for drying or leave to air-dry. Do not use hot air.
Clean daily:
• Interior chamber, inside of the door, tray and lip seal
• Container(s)
• Suction hoses
• Plug-in couplings

Cleaning of cup tray (SU12)

1. Switch off the heated cup

tray.

2. Wait for the tray to cool

down.

3. Clean the now cooled tray

with a damp microfiber cloth.
In the case of gross contami-
nation use a mild cleaner.

3.6

Malfunctions

If there is a malfunction, an error message is shown on the coffee machine
display. The error messages contain information regarding the cause and res-
olution of the malfunction.

Summary of Contents for SU12

Page 1: ...MANUAL SU12 UT12 FCS4053 en Read the user manual before working on the device Keep the manual with the device and pass the manual on to the next operator if the device is sold or transferred to a third party ...

Page 2: ......

Page 3: ...5 1 4 General safety concerns 6 2 Scope of delivery 12 3 Usage 14 3 1 Installation 14 3 2 Function 14 3 3 Function of the FoamMaster 14 3 4 Components of the cooling unit 15 3 5 Operation and care 17 3 6 Malfunctions 20 4 Decommissioning transport disposal 21 4 1 Decommissioning transport storage 21 4 2 Disposal 21 5 Technical data 22 5 1 Electrical connection data 22 ...

Page 4: ... cleaners may leave residues in the milk and beverage system The cooling unit is intended exclusively for operation indoors Please also observe the Declaration of Conformity delivered with the de vice 1 2 Non authorized use Children under the age of 8 years are not permitted to use the appliance Children or persons with restricted physical sensory or mental abilities or lack of experience and know...

Page 5: ...cified If covers side panels etc on the device are missing or not assembled 1 3 Explanation of safety instructions Observation of these safety instructions is imperative to ensure personal safety and the protection of material goods Symbol and signal word indicate the severity of the hazard WARNING WARNING indicates a potential danger DANGER indicates an im minent danger which if not avoided will ...

Page 6: ...chine and the power cord are not near any hot sur faces such as gas or electric stoves or ovens d Ensure that the power cord is not pinched and does not chafe on sharp edges e Only pull on the plug and not on the cable when disconnecting the device from the power grid WARNING Risk of fatal injury from electrocution Liquid moisture entering the appliance or leaks can lead to electrocution a Never p...

Page 7: ...sporting and installing the cooling unit make sure that no part of the refrigerant circuit is damaged b To minimize the risk of ignition this device may only be installed by a spe cialist authorized by Franke c The device must be installed in a room with sufficient space d Make sure that the device s ventilation openings are never blocked or ob structed e Maintenance work may only be performed by ...

Page 8: ...he heat generated can cause a fire a Never use power outlet strips or extension cords to connect the device to the power supply WARNING Risk of burns The heating surface of the cup tray can cause burns or a fire a Do not touch the hot surface of the heated cup tray b IN CASE OF BURNS Immediately cool the affected area and consult a doctor depending on the severity of the injury c Do not place anyt...

Page 9: ...o drink beverages could represent a health hazard a Use only fresh refrigerated milk and fresh refrigerated ready to drink beverages b Observe the storage conditions for milk and ready to drink beverages c Observe the shelf life of the milk and ready to drink beverages used CAUTION Germs in unpasteurized milk Germs in unpasteurized milk could pose a health hazard a Do not use any unpasteurized mil...

Page 10: ...k and ready to drink beverages to spoil a Only use pre cooled milk and pre cooled ready to drink beverages 2 0 5 0 C b Only store milk and ready to drink beverages in the cooling unit when the cooling unit is in operation When the cooling unit is not in operation e g overnight store milk and ready to drink beverages in a refrigerator c Clean the machine and cooling unit once a day d Only touch the...

Page 11: ...increase If the door is open for an extended period the temperature in the compart ments of the appliance may rise significantly a Only open the door of the appliance for as long as necessary Do you have any questions that are not addressed in these instructions Please do not hesitate to contact your local customer service partner Franke Customer Service or Franke Kaffeemaschinen AG in Aarburg ...

Page 12: ...maschinen AG in Aarburg Switzerland Item description Material number SU12 UT12 FCS4053 Manual set SU12 UT12 560 0006 433 SU12 UT12 FM EC 4 milk containers 4 5 l or 2 milk containers 12 l 560 0595 536 560 0006 305 SU12 UT12 FM EC 1 cleaning container or 2 cleaning containers 560 0505 698 560 0603 494 SU12 UT12 FM CM 4 milk containers 4 5 l or 2 milk containers 12 l 560 0594 418 560 0006 312 4 media...

Page 13: ...anual SU12 UT12 13 Item description Material number Reversible adapter SU12 UT12 FM CM 2OM 560 0006 338 Separating rail 560 0006 637 Wire basket option for SU12 UT12 FM CM USA 560 0651 743 Hose kit for milk bag option for SU12 UT12 FM CM USA 560 0664 869 ...

Page 14: ...k and ready to drink beverages cool Displaying the temperature of milk and other media Setting the cooling temperature Monitoring the fill level when using Franke containers for milk and ready to drink beverages Pre warming the cups and glasses on the heated cup tray for preparing hot beverages if the cooling unit is installed to the left hand or right hand side of the coffee machine Preventing un...

Page 15: ...e images shown are for reference only the actual product may vary 1 3 4 5 6 2 7 8 1 On off switch for cooling unit 2 Temperature display and temperature control 3 Switch for milk cleaning mode 4 On off switch for heated cup tray SU12 5 Cleaning agent cartridge 6 Milk medium container 1x12 l or 2x4 5 l 7 Reversible adapter milk feed cleaning 8 Heated cup tray SU12 ...

Page 16: ...s SU12 with 12 l milk container SU12 with 2 x 4 5 l milk containers for the use of 2 milk types SU12 FM CM 2OM with 2 x 4 5 l medium containers for keeping 2 milk types milk and milk drink or 1 milk type and an additional ready to drink beverage e g Cold Brew separate all the way to the cup SU12 Twin with 2 x 4 5 l milk containers for connecting 2 coffee ma chines UT12 FM under counter cooling uni...

Page 17: ... of the heated cup tray CAUTION Irritation from cleaners Cleaning tablets milk system cleaning agents and descaler can lead to irrita tions of the skin or eyes a Observe the hazard warnings on the label of the respective cleaner b Avoid contact with your eyes and skin c Wash your hands after coming into contact with cleaners d Cleaners must not find their way into drinks CAUTION Spoiled milk and r...

Page 18: ...ICE Risk of damage to the compressor If the ambient temperature is too low the compressor oil may be too viscous resulting in the compressor being inadequately lubricated and being damaged as a result a Make sure that the permissible ambient temperature is maintained De tails pertaining to climate classes can be found on the type plate and in the technical data NOTICE Spoiled milk and ready to dri...

Page 19: ...er and the con tainer lid after sanitizing your hands or wear disposable gloves e Place the container lid with the suction hose on a clean surface only NOTICE Significant temperature increase If the door is open for an extended period the temperature in the compart ments of the appliance may rise significantly a Only open the door of the appliance for as long as necessary NOTICE Formation of mold ...

Page 20: ... the coffee machine Clean the cooling unit and components with warm water and a mild cleaner Use a dry cloth for drying or leave to air dry Do not use hot air Clean daily Interior chamber inside of the door tray and lip seal Container s Suction hoses Plug in couplings Cleaning of cup tray SU12 1 Switch off the heated cup tray 2 Wait for the tray to cool down 3 Clean the now cooled tray with a damp...

Page 21: ...ient conditions provided in the technical data 4 2 Disposal Observe the information on the label when disposing of any unused cleaning supplies Contact your local authorities for safe disposal of the refrigerant used The type plate contains information about the refrigerant The appliance complies with European Directive 2012 19 EU regarding Waste Electrical and Electronic Equipment WEEE and must n...

Page 22: ...igerant R600a fill level isobutane g 12 Cooling temperature C 2 0 5 0 Climate class 4 Suitable for operation at an ambient tempera ture of max 16 32 C Ambient temperature C 16 32 Humidity Max 80 5 1 Electrical connection data Voltage Mains power connection Current con sumption max Fuse Frequency 100 V 1LNPE 1 7 A 10 A 50 60 Hz 110 127 V 1LNPE 1 7 A 10 A 60 Hz 220 V 1LNPE 0 8 A 10 A 50 Hz 220 240 V...

Page 23: ......

Page 24: ...ey Street St Albans Hertfordshire AL2 2DQ England Tel 44 1923 635700 Fax 44 1923 635701 www franke com Franke Coffee Systems Americas 800 Aviation Parkway Smyrna TN 37167 USA Tel 1 615 462 4265 Fax 1 615 462 4400 www franke com Franke Kaffeemaschinen AG Franke Str 9 CH 4663 Aarburg Switzerland Tel 41 62 787 31 31 www franke com coffee franke com Original operating instructions 20131925 04 12 22 20...