![Franke SPECTRA I Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/franke/spectra-i/spectra-i_operating-instructions-manual_2327092015.webp)
Capacity
up to 120 cups
(depending on cup size)
Power connection
200–240 V
1 L N PE 300 W 10 A 50/60 Hz
Power cable
l =2000 mm
Drain hose
d = 16 mm, l = 2000 mm
Not fixed (aerated), fitted to drain
Funnel
d = 50 mm with siphon
Drain tube
d
min
= 1"
Weight
17 kg
Width
300 mm
Depht
580 mm
Height
545 mm
Sideboard aperture
d
1
= 120 mm
Technical specifications of the cup warmer
Standard adjustable foot
h1 = 710 mm +
0–15 mm = 710–725 mm
Plastic adjustable foot
h2 = 710 mm +
45–70 mm = 755–780 mm
Metal adjustable foot
h3 = 710 mm + 85–125 mm = 795–835 mm
Adjustable feet
(Option)
Line up add-on units with the Spectra I and position at eye level.
Minimum distance to the wall is 50 mm. Headroom must be
at least 200 mm.
Thanks to the adjustable feet, surface irregularities or height
differences can be evened out.
A minimum of 300 mm width between each add-on unit is
needed.
h3
h2
h1
85
–125
45
–70
0–
1
5
min 50
min 200
Installation dimensions of the add-on units
Eye level
(depending on
body height, approx.
1.50 to 1.70 m)
Floor
Working height
(depending on
body height, approx.
0.79 to 0.99 m)
Pa
ge
1
4
In
st
al
lation and tec
hnic
al