Factory default settings are for:
• an UNFILTERED unit
• a 20-second maximum run time
1. Top cap is set aside until program is complete. Remove top cap by unscrewing two (2) T15 torx
screws, if needed.
2. Reach hand down between frame and front of cabinet to gently press button sticking up from top
of circuit board (
Note:
Circuit board runs on low voltage and will not shock you). A remote button
is available. Remove wire tie, bundling it inside bottle filler and feed it through hole in cooler top.
You can then adjust program using button through access panel of cooler.
3. To enter program mode, press and hold button for about 3 seconds. When you hear a beep, let go of
button. You are now in Program Mode. Pressing button for an instant will advance to next screen. It will
revert back to Operating Mode if no button is pressed for 10 seconds.
4. When you enter Program Mode, display screen will read “UNFILTERED UNIT.” To access settings for
“FILTERED UNIT”, press and hold button for about 3 seconds. Press button for an instant to advance to
next menu item.
5. If you wish to reset filter life counter or bottle counter, press and hold button for 3 seconds in screen
asking corresponding question.
6. Default capacity for filter life counter is 1250 gallons (to match VERSAFILTER® filter). Press and hold
button 3 seconds in “FILTER CAPACITY OF…” screen to change setting to 3000 gallons (GALAXI® green
filter media - may not be available at time of printing).
7. “Bottle Filler Set_time” screen is to adjust maximum run time once sensor is activated. Water flow will
stop once container is removed from alcove, but this feature ensures very little water is wasted if some-
one tampers with dispenser.
8. Unit is calibrated at factory, but it is recommended that sensor be recalibrated at each install. Also, if
you are having problems with sensing of a bottle, try recalibrating it before calling for service. Press and
hold button for 3 seconds to calibrate sensor in “INFRARED SENSITIVITY” screen.
9. Put top cap back on and fasten in place with two (2) torx screws.
Status / Statut
Ok
Service soon
Service Recommended
D’accord
Service bientôt
Service recommandé
BOTTLES SAVED