Franke KEP ACSL-EBF Series Installation Manual Download Page 2

2

0316 

 KEPACSL-EBF_036865-066

WARNING:

The warranty and the Underwriters’ Laboratory Listing for this machine are automatically voided if this machine is 

altered, modified, or combined with any other machine or device. Alteration or modification of this machine may cause serious flood-

ing and/or hazardous electrical shock or fire. EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, 

GUARANTEE OR AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANT ABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE.

b)  Electric eye (EE) models have a regulator built into the bubbler. If adjustment is needed, insert a 5/64" wrench approximately 1 1/8" 

into the bubbler nozzle opening until it bottoms out and is seated in an adjust screw. Turn the adjust screw clockwise to reduce the 

stream heigh or counterclockwise to increase the height. Note, less than one turn is required to go from a closed to a wide open flow. 

Do not overtighten the adjuster in the closed position as stripping the hex impression in the adjust screw may result.

14. To adjust the beam range of the sensor (EE models only):

a)   Shut off the water and power supplies.
b)   Remove the two screws from the top front.
c)   Remove the eight screws from the bottom of the nose that holds the nose to the shelf.
d)   Remove the nose to gain access to sensor adjusting screw located between the two lenses.
e)   The screw can be turned a maximum of 3/4 turns. Turn screw counterclockwise to decrease range. The sensor has an adjustable 

range of 24" to 48". It is factory set at 27". There is a non-adjustable on-time delay of .75 seconds to prevent nuisance actuation of 

the solenoid valve should someone walk by. After drinking, the water will shut off immediately after walking away. Maximum run time is 

30 seconds should someone tamper with the sensor. NOTE: Walls with a reflective finish, i.e., ceramic tile,across from the sensor may 

cause false actuation no matter what the sensor adjustment is for distance. Therefore, do not install the unit in such an area or dull the 

surface of the wall so it will not reflect light.

C. MAINTENANCE

The only maintenance operation required is the removal of dirt and lint from the condenser of the water cooler. Inspection should be made at 

3-month intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire brush when required. Observance of 

this procedure will ensure adequate air circulation through the condenser so operation is efficient and economical.

D.  OVERLOAD PROTECTION (water cooler)

The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in case of an 

overload.

E.  LUBRICATION (water cooler)

This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor on this unit seldom needs 

oiling, but if required, a few drops of SAE 10 oil should be used.

F.  TO DISCONTINUE USE OF WATER COOLER AND WATER FOUNTAIN

1.  Close water shut off valve.
2.  Provide container to catch water to be drained.
3.  Disconnect the water supply line at the water cooler “WATER SUPPLY” tube. Disconnect water cooler “DRAIN/REMOTE COLD WATER” 

tube from water fountain “WATER IN” tube. Place container under water cooler “DRAIN/REMOTE COLD WATER” tube, then push and 

hold push button on the water cooler until water cooler is completely drained. Place container under water fountain “WATER IN” tube, 

then push and hold push button on the water fountain until water fountain is completely drained.

4.   Disconnect the power supply cords.
5.   Plug both water cooler “DRAIN/REMOTE COLD WATER” tube, and water fountain “WATER IN” tube.
6.   ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER.

*American With Disabilities Act

DRINKING FOUNTAIN INSTALLATION

For All Universal Split Level KEP( )ACSL-EBF Series Drinking Fountains 

with Electronic Bottle Filler 

Summary of Contents for KEP ACSL-EBF Series

Page 1: ...the appro priate roughing in drawing The short leg of the crossover piece will be on the water cooler side When the unit has an internal waste trap the trap should be wrapped with insulating tape to...

Page 2: ...i e ceramic tile across from the sensor may cause false actuation no matter what the sensor adjustment is for distance Therefore do not install the unit in such an area or dull the surface of the wall...

Page 3: ...ES 4 PLCS ELECTRONIC EYE MODELS ONLY PUSH PAD WATER COOLER AND FOUNTAIN KEPV8ACSL PUSH BUTTON OPTIONAL GLASSFILLER LOCATION WATER COOLER 1 1 4 O D TAILPIECE AIR FLOW 1 1 4 IPS WASTE OPTIMUM LOCATION S...

Page 4: ...AILPIECE 3 8 O D WATER INLET WITH STRAINER 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1 32 941 1 2 13 2 PLCS 3 5 16 84 12 3 4 324 2 PLCS 6 3 8 162 2 PLCS AIR FLOW ELECTRONIC EYE MODELS ONLY 1 4 8 MOU...

Page 5: ...BARRIER FREE HEIGHT INSTALLATION SHOWN REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30 760 BY 48 1220 AD...

Page 6: ...nstalled onto a refrigerated drinking fountain chilled water can be dispensed through the Bottle Filler Otherwise room temperature water will be dispensed The Bottle Filler is shipped partially assemb...

Page 7: ...7 8 9 10 11 NOT PRE DRILLED BOTTLE FILLER KIT If the unit is not pre drilled or you purchased a BOTTLE FILLER retrofit KIT go to next PAGE 8 STEP 1 PRE DRILLED If your unit was purchased pre drilled...

Page 8: ...nits are single units made since December of 2009 Refer to the schematic below to identify the system that you have Mark hole location Template Remove top from cooler by removing six 15 torx head scre...

Page 9: ...1 8 po 5 4cm FROM BACK Mark this center point on the top Remove the top from the cooler Then drill a 7 8 2 2cm hole through the top at the marked centre point ALIGN THIS EDGE WITH LEFT EDGE OF COOLER...

Page 10: ...TEE fitting supplied will need to connect be tween the cooling tank and valve Figure 3 STEP 3 Disconnect tubing from the elbow on the valve Figure 4 STEP 4 Using the 30 piece of tubing provided cut 6...

Page 11: ...sser le tuyau dans le dessus et fixer ce dernier au refroidisseur Figure 10 Figure 7 TAPE 6 STEP 6 Feed tubing up through the top and attach the top to the cooler Figure 7 SECTION 2 CONNECTING THE WAT...

Page 12: ...2 Make sure to pull the plastic tubing up through the hole in the frame Use mounting slots that will provide the proper securing location Bottle filler cabinet Groove in the gasket Figure14 STEP 4 Sli...

Page 13: ...iller power supply to female terminals on power cord Make sure male tab is seated inside metal contacts of female terminal STEP 9 Plug in bottle filler cord The program should be set up specific for t...

Page 14: ...TERED UNIT press and hold button for about 3 seconds Press button for an instant to advance to next menu item 5 If you wish to reset filter life counter or bottle counter press and hold button for 3 s...

Page 15: ...15 0316 KEPACSL EBF_036865 066 1 2 3 26 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22 22 23 24 25 25 22 4 27 28 29 30 31 32 33 EXPLODED PARTS BREAKDOWN ELECTRONIC SPORTS BOTTLE FILLER...

Page 16: ...8706 036 Washer spacer gasket non metallic 18 026670 007 Screw hex heavy duty machine 19 028481 101 Fitting PP union elbow white 20 036209 001 Fill tube assembly 21 026642 003 Bracket fill tube suppor...

Page 17: ...Drinking Water Temperature Specifications subject to change without notice 115 VAC 10 1 PH 60 Hertz 35 1 4 W 18 5 8 D 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F SPECIFICATION...

Page 18: ...8 flat blade screwdriver into the slotted hole as shown The screwdriver will engage the stream height adjuster in the cartridge plunger Turn clockwise to increase stream height or counter clockwise t...

Page 19: ...ld control 027040 039 027040 039 Not applicable 23 Relay 036056 003 036056 003 Not applicable 24 Overload 036055 003 036055 003 Not applicable 25 Start capacitor 60 MFD 027956 008 027956 008 Not appli...

Page 20: ...Kindred Road Midland ON L4R 4K9 Tel 1 855 446 5663 Fax 1 866 227 3050 www franke commercial com 0316 KEPACSL EBF_036865 066 WIRING DIAGRAM Single KEP __ series Split Level KEP __ series WIRING DIAGRAM...