Fitting the hood body – Recirculation Version
• Detach the 2 brackets that can be seen inside the
opening on the top part of the hood canopy.
• Rest the Hood Canopy
1
on the Suction Unit
3
,
inserting it, and fix it at the side using the 2 screws
12b
.
• Position the directional grille
8
on the pipe and check
that it has been fitted properly.
• Fasten the directional grille
8
using the screws
12e
provided.
• Make sure that the Activated charcoal odour filter has
been fitted.
8
12e
7
12b
Electrical connection
• Connect the Hood to the Mains Power Supply, inserting
a bipolar switch with a contact aperture of at least 3
mm.
• Remove the filter and make sure that the Power cable
has been properly inserted into the Suction fan socket
• Take the control box inside the suction unit
3
and slot it
into the plastic support provided for it in the hood
canopy at the height of the controls.
• Pass an fix the wiring through with the Adhesive cable
tie already mounted.
• Fasten the Spotlights connector
Lux
.
• For the Recirculation Version, fit the Activated
Charcoal Odour Filter.
• Replace the metal grease filters.