![background image](http://html1.mh-extra.com/html/franke/fsw-918-tc-w-bk-xs-ch/fsw-918-tc-w-bk-xs-ch_instructions-for-use-and-installation_2328051012.webp)
EN
2
23
Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when the
F
button LED on the
display starts to flash, or at least once every 4 months. The Alarm signal must be activated in
advance.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press
F
and
hold for approximately 4 seconds, after which:
• The LEDS on buttons
F
and
B
flash twice: Activated Charcoal filter saturation alarm
ACTIVATED
• The LEDS on buttons
F
and
B
flash once: Activated Charcoal filter saturation alarm
DEACTIVATED
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• With the filter alarm on, press button
F
briefly (see the para-
graph on USE).
Changing the Filter
• If closed, open the door by pressing button
H
and holding for
approximately 2 seconds (see USE).
• Remove grease filters.
• Remove the saturated activated charcoal filters, as indicated
(
A
).
• Fit the new filters, as indicated (
B
).
• Replace the metal grease filters.
A
B