Hood body installation
• Before hooking the hood body it is necessary to tighten 2
Vr
screws
placed in the fixing points of the body.
• Hook the hood body on the
12a
screws.
• Tighten
completely
12a
support screws.
• The correct hood body position can be levelled with
Vr
screws.
• Fix the hood definitively by tightening the
12a
security screw.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
9
ø 120
ø 150
RECIRCULATION VERSION AIR OUTLET
• Insert the connection extension pieces laterally
14.1
in connec-
tion
15.
• Insert the Connector
15
into the Support bracket
7.3
and fix it
with a screw.
• Make sure that the outlet of the extension pieces
14.1
is hori-
zontally and vertically aligned with the chimney outlets.
• Connect the air outlet connection
15
to the hood body outlet
using either a flexible or rigid pipe ø 150 mm, the choice of
which is left to the installer.
• Ensure that the activated charcoal filters have been inserted.
ø 150
15
14.1
7.3