19
Important
When converting the appliance to a different type of gas, place the corresponding sticker (supplied as an accessory) in
the special space on the dataplate. For operation with LPG. (G30 or G31), the minimum flame adjustment screw must
be fully screwed down. These appliances are supplied in cat. II 2H3+.
Minimum flame adjustment
Highest minimum
adjustment
Lowest
minimum
adjustment
fig. 7
– Remove the knobs (push-on type).
– Light the burners and adjust the minimum flame by turning the adjustment
screw clockwise to decrease the flame and anticlockwise to increase it
(fig. 7). The screwdriver for adjustment is supplied with the accessories.
Technical Data
Technical data
FHNE 604 3G TC XS
Appliance category:
II 2H3+
(G20=20mbar >> G30/G31=28-30/37mbar)
BURNERS
NOMINAL
POWER (kW)
REDUCED
POWER (kW)
NOMINAL
CAPACITY G20
(m³/h)
INJECTORS
G20
20 mbar
(100/mm)
NOMINAL
CAPACITY G30/
G31
(g/h)
INJECTORS
G30/G31
28-30/37 mbar
(100/mm)
MAX
RECOMMENDED
POTS (mm)
Auxiliary
1.00
0.65
0.095
72
73
50
140
Semi-rapid LH
1.75
0.70
0.167
97
127
65
200
Semi-rapid RH
1.75
0.70
0.167
97
127
65
200
Triple crown
3.60
2.10
0.343
128
262
96
260
TOTAL INSTALLED NOMINAL GAS POWER (kW)
8.10
TOTAL NOMINAL CAPACITY - GAS G20 (m³/h)
0.772
TOTAL NOMINAL CAPACITY - GAS G30/G31 (g/h)
589
POWER / VOLTAGE / CURRENT / FREQUENCY
0.6 W / 220-240 V / 16 A / 50-60 Hz
AIR NECESSARY FOR COMBUSTION (2 m³/h per kW of installed nominal gas power)
16.20
Technical data
FHNE 755 4G TC
Appliance category:
II 2H3+
(G20=20mbar >> G30/G31=28-30/37mbar)
BURNERS
NOMINAL
POWER (kW)
REDUCED
POWER (kW)
NOMINAL
CAPACITY G20
(m³/h)
INJECTORS
G20
20 mbar
(100/mm)
NOMINAL
CAPACITY G30/
G31
(g/h)
INJECTORS
G30/G31
28-30/37 mbar
(100/mm)
MAX
RECOMMENDED
POTS (mm)
Auxiliary
1.00
0.65
0.095
72
73
50
140
Semi-rapid
1.75
0.70
0.167
97
127
65
220
Rapid
3.00
1.30
0.286
115
218
85
240
Triple crown
3.80
2.10
0.362
133
277
97
260
TOTAL INSTALLED NOMINAL GAS POWER (kW)
11.30
TOTAL NOMINAL CAPACITY - GAS G20 (m³/h)
1.077
TOTAL NOMINAL CAPACITY - GAS G30/G31 (g/h)
822
POWER / VOLTAGE / CURRENT / FREQUENCY
0.6 W / 220-240 V / 10 A / 50-60 Hz
AIR NECESSARY FOR COMBUSTION (2 m³/h per kW of installed nominal gas power)
Summary of Contents for FHNE 1204 3G TC
Page 3: ...3 FHNE 805 4G TC FHNE 805 4G TC FM 4 3 6 1 FHNE 755 4G TC 2 4 2 6 1 Fig 2b Fig 2c 2...
Page 7: ...52 1070 1090 410 390 FHNE 1204 3G TC Fig 3n FHNE 1204 3G TC FM Fig 3m Fig 3l Fig 3i 6...
Page 51: ...50 50 50 50 51 51 51 52 55 Franke 1 2 3 4 3 604 1204 1 1204 3 4 55 30...
Page 52: ...51 Art S N...
Page 53: ...52 OFF 3 3 FHNE 755 4G TC FHNE 805 4G TC 4...
Page 54: ...53 FHNE 805 4G TC FM FHNE 1204 3G TC FM 3 3 5 54 6 A 12 mm 6 A O 1 100 cm2 2 3 4 1 2 3...
Page 65: ...64 64 64 64 65 65 66 68 Franke 1 2 3 4 3 604 1204 1 1204 Dual 3 4 Dual Dual 68 30...
Page 66: ...65 Art S N...
Page 67: ...66 3 3 FHNE 755 4G TC FHNE 805 4G TC 2 FHNE 805 4G TC FM FHNE 1204 3G TC FM 3 3e 5...