5.11 COMPACT EK MODEL ALARM MANAGEMENT
LED CORRESPONDING TO THE COFFEE DOSE BEING DELIVERED, FLASHING AFTER 5-6 SECONDS:
Too fine grinding.
Failed reading of the pulses sent by the flow meter to the delivery group.
ALL LEDS CORRESPONDING TO ALL DOSES ON ALL TOUCHPADS FLASHING:
The automatic filling function for the boiler tank has been operating for more than 4 minutes, total machine block. To return to the stand-
ard operating phase, switch the machine off using the main On/OFF switch.
If the problem keeps occurring several times, verify the automatic boiler filling system.