4. Important Notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
•
5526 11 24-F:
Secure the electric connection with an earth leakage circuit
breaker (RCD).
• All rights reserved to make technical alterations.
5. Application
Complete installation kit for PROTRONIC - non-touch, opto-electronically controlled
urinal flush-valve DN 15 for in-wall installation. Individual control unit in compact
design. Automatic forced flushing after 24 hours of non-use.
Optional: Function parameters adjustable by remote control.
5526 11 24-F … with mains connection
5526 12 24-F … for separate power supply
6. Technical Specifications
Minimum flow pressure:
1.0 bar
Recommended flow pressure:
1-4 bar
Maximum operating pressure:
10 bar
Calculation flow rate:
0.30 l/s
Flushing flow rate:
0.3 – 0.7 l/s
Flush water volume:
2 – 4 l
Flushing duration
0.6 – 6.5 s (adjustable in 6 steps)
Operating voltage:
5526 11 24-F
230 V AC, 50/60 Hz
5526 12 24-F
24 V DC
Operating voltage:
24 V DC
Power consumption:
5526 11 24-F
2.5 VA
5526 12 24-F
3 W
Type of protection:
IP 54