12
18
-05
.81
3
e
-G
B.f
m
19. Replacing the Thermocouple
Warning!
After installing the fitting or removing the thermocouple, adjust the scald protector.
Failure to observe can cause bodily harm due to scalding.
19.1
Close the flow volume regulators (see
19.2
Trigger the valve.
19.3
Remove the cover platelet (a).
19.4
Loosen the screw (b).
19.5
Remove the temperature selection knob (c) and the stop ring (d).
19.6
Pull out the bracket (k).
19.7
Remove the brass stop ring (l).
19.8
Turn the plastic sliding washer (m) and the regulating screw (n) in a clockwise
direction.
19.9
Unscrew the thermocouple (o) with an open-end spanner.
19.10
Reassemble in the reverse order.
☞
Important!
The rib (i) of the brass stop ring (l) must be in the 12 o'clock position when assembling.
19.11
Adjusting the Scald-protector (see
20. Replacing the Flow Rate Regulator
20.1
Loosen the grub screw using a hollow hexagon wrench.
20.2
Pull the shower head from the connection spigot.
20.3
Remove the safety ring with the appropriate pliers for the inner safety rings.
20.4
Pull out the flow rate controller with flat nose pliers.
20.5
Replace the flow rate regulator. Note details provided in the table.
20.6
Remove the circlip with an appropriate pliers for inward circlips.
20.7
Pull out the flow rate regulator with a flat nose pliers.
20.8
Replace the flow rate regulator. Note details provided in the table.
☞
Important!
Ensure correct installation orientation of the flow rate regulator. The brace must face in
the direction of the head piece.
20.9
Insert the flow rate regulator and secure with the circlip.
a: Brace
b: Flow direction
20.10
Reassemble in the reverse order.
Flow rate
Flow rate regulator
0.15 l/s (orange)
FAR Order No. 81-100-20.077
0.20 l/s (red)
FAR Order No. 81-100-20.078