8
ZMI
_001_
2030
021
142
-A
T3O0
051_#
SEN_#
AQU_
#V1.
fm
12. Setting the hygiene flush
The hygiene flush can be adjusted with an ECC2 function controller via the web
application.
13. Maintenance and care
The fitting must be checked and maintained at regular intervals, depending on the
water quality and in accordance with the local conditions and rules and regulations
applicable at the site.
Use suitable cleaning agents which do not attack the fitting in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
14. Troubleshooting
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!
15. Spare parts
Fault
Cause
Remedy
Water does not flow
– Water supply interrupted
➯
Restore it
– Angle valve closed
➯
Open it
– Electronics module faulty
➯
Replace it
Water flows continu-
ously
– Motor faulty
➯
Replace it
Accessories
Order No.
System cable for long-term use in water,
halogen-free 100 m . . . . . . . . . 2000104272
halogen-free 25 m . . . . . . . . . . 2000104274
System cable,
not halogen-free 100 m . . . . . . 2000100801
not halogen-free 25 m . . . . . . . 2000100852
* When ordering please specify the fitting ID!
The fitting ID can be found on the side of the
electronic module.
Description
Order No.
1 Cover plate complete . . . . . . . . . . 2000105718
2 Piezo button set . . . . . . . . . . . . . . 2000104441
3 Motor. . . . . . . . . . . . . . . . . . . . . . . 2030022899
4 Electronic module* . . . . . . . . . . . . 84-100-17.109
5 Electrical T-distributor . . . . . . . . . . 2000100853